Impulse switch, 1 NO contact 16 A image 1

Impulse switch, 1 NO contact 16 A

Noliktavas cena (bez PVN):
36,50 €
Šī cena ir spēkā līdz 2024-12-31
Cena par m: 36,50 €
EAN: 4010312107959
MPN: 21100002
Mūsu noliktava: Piegādātāja krājumi:
Vienā iepakojumā: 1 Vienā kastē: 1 Vienā paletē: N/A
Tehniskie dati
Preces stāvoklis Jauns
Zīmols ELTAKO
Kategorijas Releji
Izcelsmes valsts CN
Harmonizētās sistēmas kods 8536 5080 00
Montāžas metode DIN sliede
Funkcija Elektroniskais slēdzis
Iebūvēts dziļums 58 mm
Platums moduļu atstarpju skaitā 1
Vadības spriegums 1 8-230 V
Vadības spriegums 2 230 V
Vadības sprieguma veids 1 AC/DC
Vadības sprieguma veids 2 AC
Frekvences vadības spriegums 1 50 Hz
Frekvences vadības spriegums 2 50 Hz
Piemērots manuālai darbībai No
Maks. pārslēgšanas strāva (cos phi = 0,6) 4 A
Maks. kvēlspuldžu slodze 2000 W
Maks. slodzes dienasgaismas spuldze 1000 VA
Maks. slodzes dienasgaismas spuldze (Duo ķēde) 1000 VA
Maks. slodzes dienasgaismas spuldze (paralēli kompensēta) 500 VA
Nominālā slēdža strāva 16 A
Kontaktu skaits kā parasti slēgtam kontaktam 0
Kontaktu skaits kā parasti atvērtam kontaktam 1
Kontaktpersonu skaits kā maiņas kontaktpersona 0
Iepakojuma informācija
Iepakojuma līmenis 1 4010312107959, 4010312107959
Iepakojuma līmenis 2 4010312107959
Iepakojuma līmenis 3 4010312107959
Downloads
Apraksts
1 NO contact potential free 16A/250V AC. 230V LED lamps up to 600W, incandescent lamp load up to 2000W. No standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. With the patented Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 1(L) for this. This results in an standby consumption of only 0.1 watt. If the contact is used for controlling switching devices which do not perform zero passage switching themselves, (N) should not be connected because the additional closing delay otherwise causes the opposite effect. Either universal control voltage 8 to 230V UC at the control input +A1/A2 or 230V with glow lamp current up to 5mA at the control input (L)/-A2 (N). The simultaneous use of two potentials at the control inputs is not permitted. Very low switching noise. No permanent power supply necessary, therefore no standby loss. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation. Same terminal connection as the electromechanical impulse switch S12-100-. If this impulse switch is in a circuit, which is monitored by a FR12-230V mains dis­connection relay, no additional base load is required. However, the monitoring voltage of the FR12-230V must be set to max. Control only through A1-A2. The electronics does not have an internal power supply and therefore no power is consumed in any ­contact position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.