Technical Information
Preces stāvoklis |
Jauns |
Ražotāja nosaukums |
Impulse switch, 1 NO contact 10A |
Zīmols |
ELTAKO
|
Kategorijas |
Releji
|
Izcelsmes valsts |
CN |
Harmonizētās sistēmas kods |
8536 5080 00
|
Montāžas metode |
Citi |
Funkcija |
Citi |
Iebūvēts dziļums |
18 mm |
Platums moduļu atstarpju skaitā |
3.1 |
Vadības spriegums 1 |
8-230 V |
Vadības spriegums 2 |
230 V |
Vadības sprieguma veids 1 |
AC/DC |
Vadības sprieguma veids 2 |
AC |
Piemērots manuālai darbībai |
No |
Barošanas sprieguma sprieguma veids |
AC |
Barošanas spriegums |
250 V |
Maks. pārslēgšanas strāva (cos phi = 0,6) |
4 A |
Maks. kvēlspuldžu slodze |
2000 W |
Maks. slodzes dienasgaismas spuldze |
1000 VA |
Maks. slodzes dienasgaismas spuldze (Duo ķēde) |
1000 VA |
Maks. slodzes dienasgaismas spuldze (paralēli kompensēta) |
500 VA |
Nominālā slēdža strāva |
10 A |
Kontaktu skaits kā parasti slēgtam kontaktam |
0 |
Kontaktu skaits kā parasti atvērtam kontaktam |
1 |
Kontaktpersonu skaits kā maiņas kontaktpersona |
0 |
Iepakojuma informācija
Iepakojuma līmenis 1 |
4010312107966, 4010312107966 |
Iepakojuma līmenis 2 |
4010312107966 |
Iepakojuma līmenis 3 |
4010312107966 |
Lejupielādes
Apraksts
1 NO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load up to 2000W. No standby loss. For installation. 45mm long, 45mm wide, 18mm deep. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. Either universal control voltage 8 to 230V UC at the control input +A1/-A2 or 230V with a glow lamp current up to 5mA at the control input (L)/-A2(N). Using two potentials simultaneously at the control inputs is not permitted. Very low switching noise. No permanent power supply necessary, therefore no standby loss. By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation. If this impulse switch is in a circuit, which is monitored by a FR12-230V mains disconnection relay, no additional base load is required. However, the monitoring voltage of the FR12-230V must be set to max. The electronics does not have an internal power supply and therefore no power is consumed in any contact position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.