Register to unlock your exclusive B2B prices. Register now
RS485 bus actuator 2-speed fan relay image 1

RS485 bus actuator 2-speed fan relay

Noliktavas cena (bez PVN):
54,38 €
Šī cena ir spēkā līdz 2024-12-31
Cena par m: 54,38 €
EAN: 4010312316160
MPN: 30014067
Mūsu noliktava: Piegādātāja krājumi:
Vienā iepakojumā: 1 Vienā kastē: 1 Vienā paletē: N/A
Tehniskie dati
Preces stāvoklis Jauns
Ražotāja nosaukums RS485 bus actuator 2-speed fan relay
Zīmols ELTAKO
Kategorijas Gaismas slēdži
Izcelsmes valsts CN
Harmonizētās sistēmas kods 8526 9200 00
Montāžas metode Citi
Krāsa Pelēks
Nesatur halogēnus Yes
Virsmas aizsardzība Citi
Pašreizējais piedāvājums Citi
Releju skaits 2
Piemērots slēdzim Yes
Piemērots pulsa pogai Yes
Piemērots dimmeram No
Piemērots rullo slēģu slēdzim No
Materiāla kvalitāte Termoplasts
Materiāls Plastmasas
Stiprinājuma veids Citi
Ritošā koda sistēma -
Radio frekvences 868 MHz
Mājoklī Yes
Caurules pamatnes korpusā No
Iespiedshēmas plate/modulis No
Spiedpogas režīms Yes
Pārslēgšanas režīms Yes
Ar manuālo radio raidītāju No
Ar radio kodēšanas ierīci No
Ar radio vadāmu spiedpogu No
Piemērots venēcisko/rullo slēģu slēdzim No
Piemērots Venēcijas slēģu slēdzim No
Caurspīdīgs No
Virsmas apdare Matt
Piemērots aizsardzības pakāpei (IP) IP20
Ir pieejams IFTTT atbalsts No
Savietojams ar Apple HomeKit No
Savietojams ar Google palīgu No
Savietojams ar Amazon Alexa No
Iepakojuma informācija
Iepakojuma līmenis 1 4010312316160, 4010312316160
Iepakojuma līmenis 2 4010312316160
Iepakojuma līmenis 3 4010312316160
Downloads
Apraksts
2-speed fan relay, 1+1 NO contacts potential free 16A/250V AC, with DX tech­nology. Bidirectional. Only 0.1 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Patented Eltako Duplex technology allows you to switch normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N1) and L to 1(L) and/or N to (N2) and L to 3(L). This ­results in an additional standby consumption of only 0.1 watt. If supply voltage fails, the switching state is retained. When supply voltage is ­restored, the device is switched off in defined mode. This fan relay evaluates the information of up to 23 passive sensors, e.g. wireless pushbuttons, window/door contacts, window handle sensors FFG7B-rw or wireless transmitter modules. Active sensors for CO2, air quality, humidity and temperature are also evaluated. Several active sensors can be linked by the PCT14 PC Tool. When the two contacts are switched in parallel, the 2-speed actuator for 2 fan speeds becomes an actuator for one fan. The middle rotary switch must be set to position LRN for teach-in. Set the required operating mode when the fan actuator is in operation. During the teach-in process, adjust the upper rotary switch to set the sensor type. A wireless pushbutton (exclusive) with double rocker is taught-in in rotary switch position 1. Double rockers are assigned automatically: top left Stage 1 (only contact 1-2 closed), top right stage 2 (only contact 3-4 closed). Bottom left and bottom right OFF: both contacts open. A wireless pushbutton (adding) with double rocker is taught-in in rotary switch position 2. Double rockers are assigned automatically: top left stage 1 (contact 1-2 closed), top right Stage 2 (contacts 1-2 and 3-4 closed). Bottom left and bottom right OFF: both contacts open. If you switch the two contacts in parallel, one wireless pushbutton and 1 rocker are sufficient. In this case, top is ON and bottom is OFF. In rotary switch position 3, teach in ON/OFF switch with double rocker (all rockers are assigned automatically) and wireless transmitter modules When you teach in an FTK device, window handle sensor FFG7B-rw or active sensor, there is no need to take the teach-in position into account. When operated with an active sensor, set the switch-in threshold on the lower rotary switch. When the threshold is reached, Stage 1 (Contact 1-2) is switched on. At the upper rotary switch, set the addition value at which Stage 2 (Contact 3-4). Turn the middle rotary switch to set one of the operating modes AUTO1 to AUTO7. AUTO1: for manual mode of a 2-stage fan by means of a double rocker wireless pushbutton. Each contact is closed separately (exclusive) or contact 3-4 cuts in to switch stage 2 (accumulative). This is determined when teaching-in. Passive sensors, such as wireless pushbuttons and transmitter modules, which are taught-in as a off-switches, cause opening of both contacts. As long as the control voltage is applied to transmitter modules or a window monitored by an FTK or window handle sensor FFG7B-rw is open, the contacts are open and can not be switched on manually. AUTO2: Activating with either a wireless CO2 or air quality sensor. The switch-on thresholds are set by the lower and upper rotary switches. The contacts close exclusively. AUTO3: Activating with wireless CO2 sensor. The switch-on thresholds are set by the lower and upper rotary switches. The contacts close exclusively. AUTO4: Same as AUTO2, but activated by the wireless temperature sensor. AUTO5: Same as AUTO2, but the contacts close adding. AUTO6: Same as AUTO3, but the contacts close adding. AUTO7: Same as AUTO4, but the contacts close adding. Overview of switch-on thresholds for CO2, air quality, humidity and temperature see operating instructions. The LED below the upper function rotary switch performs during the teach-in process according to the operating ­instructions. It shows control commands by short flickering during operation.