RS485 bus actuator multifunction impulse switch with iIntegrated relay function image 1

RS485 bus actuator multifunction impulse switch with iIntegrated relay function

Noliktavas cena (bez PVN):
47,09 €
Šī cena ir spēkā līdz 2024-12-31
Cena par m: 47,09 €
EAN: 4010312313725
MPN: 30014003
Mūsu noliktava: Piegādātāja krājumi:
Vienā iepakojumā: 1 Vienā kastē: 1 Vienā paletē: N/A
Tehniskie dati
Preces stāvoklis Jauns
Ražotāja nosaukums RS485 bus actuator multifunction impulse switch with iIntegrated relay function
Zīmols ELTAKO
Kategorijas Sensori
Izcelsmes valsts CN
Harmonizētās sistēmas kods 8526 9200 00
Montāžas metode DRA (adapteris uz DIN sliedes)
Nominālā strāva 16 A
Izejas jauda 2000 W
Nominālais darba spriegums 12 V
Autobusu sistēma KNX No
Autobusu sistēmas radio bieži Yes
Autobusu sistēma Powernet No
Maks. pārslēgšanas jauda 2000 W
Ar autobusa savienojumu Yes
Maks. pārslēgšanas kontaktu skaits 1
Platums moduļu atstarpju skaitā 1
Maks. pārslēgšanas strāva 16 A
Citas autobusu sistēmas Nav
Autobusu sistēma LON No
Piemērots C-slodzei -
Savienojamas dažādas fāzes No
Vietējā darbība/rokas darbība No
Aizsardzības pakāpe (IP) IP20
Ar LED indikāciju No
Moduļu paplašināšana No
Autobusu sistēma KNX radio No
Radio bieži divvirzienu Yes
Autobusa modulis noņemams Yes
Maks. pārslēgšanas jaudas LED 400 W
Iepakojuma informācija
Iepakojuma līmenis 1 4010312313725, 4010312313725
Iepakojuma līmenis 2 4010312313725
Iepakojuma līmenis 3 4010312313725
Downloads
Apraksts
Multifunction impulse switch with integrated relay function, 1+1 NO ­potential free 16A/250V AC, 230V LED lamps up to 400W, incandescent lamps 2000W, with DX ­technology. Bidirectional. Only 0.1-0.6 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Patented Eltako Duplex technology allows you to switch normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and L to K(L). This results in an additional standby consumption of only 0.1 watt. Maximum current over both contacts 16A for 230V. If supply voltage fails, the device is switched off in defined mode. When both relays of the FMS14 are switched on, 0.6 watt are required. The upper and the middle rotary switches are for teaching-in the sensors. In normal mode, the middle rotary switch is then set to AUTO and the bottom rotary switch to the required function: 2S = Impulse switch with 2 NO contacts. (2xS) = 2-way impulse switch each with one NO relay. WS = Impulse switch with 1 NO contact and 1 NC contact (0.3 watt standby loss). SS1 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 1. SS2 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 2. SS3 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 3. GS = Impulse group switch 1+1 NO ­contacts. 2R = Switching relay with 2 NO contacts. WR = Switching relay with 1 NO contact and 1 NC contact (0.3 watt standby loss). RR = Switching relay (closed-circuit current relay) with 2 NC contacts (0.5 watt standby loss). GR = Group relay 1+1 NO contacts. Switching sequence SS1: 0 - contact 1 (K-1) - contact 2 (K-2) - contact 1 + 2. Switching sequence SS2: 0 - contact 1 - contact 1 + 2 - contact 2. Switching sequence SS3: