Technical Information
Preces stāvoklis |
Jauns |
Ražotāja nosaukums |
RS485 bus actuator for shading elements and roller shutters 12-24V DC motor |
Zīmols |
ELTAKO
|
Kategorijas |
Sensori
|
Izcelsmes valsts |
CN |
Harmonizētās sistēmas kods |
8526 9200 00
|
Montāžas metode |
DRA (adapteris uz DIN sliedes) |
Strāvas veids |
DC |
Autobusu sistēma KNX |
No |
Autobusu sistēmas radio bieži |
Yes |
Autobusu sistēma Powernet |
No |
Maks. pārslēgšanas jauda |
4 W |
Ar autobusa savienojumu |
Yes |
Maks. žalūziju izeju skaits |
2 |
Pārslēgšanas strāva (pretestība) |
4 A |
Platums moduļu atstarpju skaitā |
1 |
Autobusu sistēma LON |
No |
Vietējā darbība/rokas darbība |
Yes |
Ar slēdža funkciju |
Yes |
Ar LED indikāciju |
No |
Autobusu sistēma KNX radio |
No |
Radio bieži divvirzienu |
Yes |
Autobusa modulis noņemams |
Yes |
Iepakojuma informācija
Iepakojuma līmenis 1 |
4010312326701, 4010312326701 |
Iepakojuma līmenis 2 |
4010312326701 |
Iepakojuma līmenis 3 |
4010312326701 |
Lejupielādes
Apraksts
Switch actuator for shading elements and roller shutters for one 12-24V DC motor. 1+1 NO contact 4A/12-24V DC, potential free from power supply 12V. Bidirectional. Only 0.1 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Connection to the Eltako RS485 bus. Bus cross wiring and power supply with jumper. The DC voltage for the motor is connected to terminals - and +, the DC motor to terminals 1 and 2. If relays of the FSB14 are switched on, a power of 0.4 watts is required. If supply voltage fails, the device is switched off in defined mode. The pushbuttons can be taught-in either as direction switches or universal switches: Local control with universal pushbutton: Each scanning pulse changes the switch position in the sequence Up, Stop, Down, Stop. Local control with direction pushbutton: Each scanning pulse up activates the switch position Up. A scanning pulse down, on the contrary, activates the switch position Down. The next scanning pulse in the same direciton interrupts the sequence immediately. However, a scanning pulse in the opposite direction stops and then switches over to the opposite direction after a pause of 500ms. Central control dynamic without priority: With a control signal from a button taught in as a central control button without priority, the switching position up at the top or down at the bottom is specifically activated. No priority because this function can be overridden by other control signals. Central control dynamic with priority: A control signal of min. 2 seconds from a pushbutton which was taught-in as a central control pushbutton with priority directly activates the switch position Up (press top) and the switch position Down (press bottom). With priority because these control signals cannot be overridden by other (local) control signals until the central control signal is cancelled by pressing again the central control pushbutton Up or Down. The switch position up or down and the priority are specifically activated with a control signal, e.g. from a FSM61 taught-in with priority as a central pushbutton. With priority because these control signals cannot be overridden by other control signals until the central command is cancelled by the termination of the control signal. Shading scene control: Up to 4 saved Down running times are retrievable using the control signal of a pushbutton and double rocker taught-in as a scene pushbutton. With control via Professional Smart Home controller, operating commands for up and down with the exact travel time information can be started. As the actuator reports the exact elapsed time after each activity, even when driving was triggered by a pushbutton, the position of the shading is always displayed correctly by a Professional Smart Home controller. Upon reaching the end positions above and below the position is automatically synchronized. Function rotary switch below: AUTO 1 = In this position, the local advanced automatic reversing system for Venetian blinds is activated. When a universal pushbutton or a direction pushbutton are used for control a double impulse activates a slow rotation in the opposite direction, which can be stopped with a further impulse. AUTO 2 = In this position, the local advanced automatic reversing system for Venetian blinds is completely switched off. AUTO 3 = In this position, the local pushbuttons act static at first, thus, allow reversal of Venetian blinds by operating pushbuttons. They only switch to dynamic after 0.7 seconds continuous operation. AUTO 4 = In this position, the local pushbuttons act only static (ER function). The time delay RV (wiping time) of the upper rotary switch is active. Central control is not possible. Arrow up/arrow down = Arrow up (UP) and arrow down (DOWN) of the lower rotary switch are the positions for manual control. Manual control has priority over all other control commands. WA = Automatic reversal for Venetian blinds and awnings is controlled by the middle rotary switch. 0 = OFF, otherwise from 0.3 to 5 seconds ON with the selected reversal time. In this case, it is only for DOWN that the direction is reversed on time-out of the time lag selected by the top rotary switch, e.g. to extend awnings or set Venetian blinds to a defined position. A LED is located behind the RV-rotary switch to show the reversal time. RV = The time delay (delay time RV) is set by the top rotary switch. If the FSB14 is in the UP or DOWN position the selected delay time runs (elapses). At time-out the device changes automatically to STOP. Therefore, the time delay must be chosen at least as long as the shading element or roller shutter will need to move from one limit position to the other. The LED indication for the delay time RV is located behind the rotary switch RV. When one or several wireless window/door contacts FTK or window handle sensors FFG7B are taught-in, a lock-out protection is set up while the door is open and disables a Central Down command. The LED below the upper function rotary switch performs during the teach-in process according to the operating instructions. It shows control commands by short flickering during operation.