Register to unlock your exclusive B2B prices. Register now
RS485 bus weather data gateway for multi sensor MS image 1

RS485 bus weather data gateway for multi sensor MS

Noliktavas cena (bez PVN):
50,61 €
Šī cena ir spēkā līdz 2024-12-31
Cena par m: 50,61 €
EAN: 4010312316887
MPN: 30014072
Mūsu noliktava: Piegādātāja krājumi:
Vienā iepakojumā: 1 Vienā kastē: 1 Vienā paletē: N/A
Tehniskie dati
Preces stāvoklis Jauns
Ražotāja nosaukums RS485 bus weather data gateway for multi sensor MS
Zīmols ELTAKO
Kategorijas Sensori
Izcelsmes valsts CN
Harmonizētās sistēmas kods 8526 9200 00
Montāžas metode DRA (adapteris uz DIN sliedes)
Modelis Vairāki interfeisi
Sprieguma veids DC
Elektrības patēriņš 0.3 W
Autobusu sistēma KNX No
Autobusu sistēmas radio bieži Yes
Autobusu sistēma Powernet No
Platums moduļu atstarpju skaitā 1
Citas autobusu sistēmas Citi
Autobusu sistēma LON No
Demontāžas aizsardzība No
Radio interfeiss No
IR interfeiss No
Protokols Citi
Atkarīgs no pakalpojumu sniedzēja No
Atjaunināms No
Vizualizācija No
Web serveris No
Darba spriegums 5 V
Aizsardzības pakāpe (IP) IP20
Ar LED indikāciju No
Autobusu sistēma KNX radio No
Radio bieži divvirzienu No
Iepakojuma informācija
Iepakojuma līmenis 1 4010312316887, 4010312316887
Iepakojuma līmenis 2 4010312316887
Iepakojuma līmenis 3 4010312316887
Downloads
Apraksts
Weather data gateway for multi sensor MS. Bidirectional. Only 0.3 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. A multisensor MS at the gateway is connected to terminals RSA and RSB. The information is received once per second and converted into bus telegrams. However, several FWG14MS can be connected to a multisensor MS e.g. to control several Eltako RS485 buses with only one MS multisensor. Only at one FWG14MS must the end resistor connected. At additional FWG14MS, this resistor must be removed. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Operation in conjunction with FAM14 or FTS14KS. The Hold terminal is connected to the FAM14 or the FTS14KS. A maximum of two FWG14MS devices can be operated in one bus. The telegram duplicator FTD14 can also send telegrams over the Wireless Building System after the IDs of the FGW14MS are taught in the FTD14 or entered using the PTC14. Receiving devices can then be FSB14, FSB61NP and FSB71. If the multisensor MS signal is not received, an alarm telegram is sent. Using the PC Tool PCT14, 96 inputs can be AND or OR linked and up to 12 outputs can be output. The BA operating mode rotary switch can be configured according to the operating instructions.