Reģistrējieties, lai atbloķētu savas ekskluzīvās B2B cenas un sāktu iepirkties. Reģistrējieties tagad!
RS485 bus wireless single-phase energy meter transmitter module 65A image 1

RS485 bus wireless single-phase energy meter transmitter module 65A

Ir noliktavā: Nē Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Cena (bez PVN):
67,24 €
Šī cena ir spēkā līdz 31.12.24
EAN: 4010312501511
MPN: 30014050
Iepakojums: 1

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums RS485 bus wireless single-phase energy meter transmitter module 65A
Zīmols ELTAKO
Kategorijas Sensori
Izcelsmes valsts CN
Harmonizētās sistēmas kods 9028 3011 00
Modelis Enerģijas skaitītājs
Savienojuma veids Tiešais
Autobusu sistēma KNX No
Autobusu sistēmas radio bieži Yes
Autobusu sistēma Powernet No
Tarifu slēdzis No
S0 impulsu saskarne Nav
Reaktīvā jauda -
Precizitātes klase 1
Apstiprināts saskaņā ar PTB No
Citas autobusu sistēmas Nav
Autobusu sistēma LON No
Autobusu sistēma KNX radio No
Radio bieži divvirzienu No

Iepakojuma informācija

Iepakojuma līmenis 1 4010312501511, 4010312501511
Iepakojuma līmenis 2 4010312501511
Iepakojuma līmenis 3 4010312501511

Lejupielādes

Apraksts

Wireless single-phase energy meter transmitter module, maximum current 65A. Only 0.5 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Accuracy class B (1%). With RS485 interface. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. The meter reading, the current power and the serial number will be handed over to the bus – eg for forwarding to an external computer, an Professional Smart Home controller – and also to the wireless network via FAM14. For this it is necessary that a device address is assigned from the wireless antenna module FAM14, according to the manual. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power is not metered. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1 phase conductor with a max. current up to 65A can be connected. The inrush current is 40mA. In operation the rotary switch must be set to AUTO. Power consumption is indicated using a LED. If the L input and the L output were interchanged when hooked up, a normal rate (HT)/off-peak (NT) switch­over telegram is transmitted to indicate the hook-up error. If the anticipated load exceeds 50%, maintain an air gap of ½ pitch unit to the devices mounted adjacently. Thereto included are 2 spacers DS14, a short jumper and two long jumpers.