Technical Information
Preces stāvoklis |
Jauns |
Ražotāja nosaukums |
Analogue settable multifunction time relay, 1 NO contact 10A |
Zīmols |
ELTAKO
|
Kategorijas |
Releji
|
Izcelsmes valsts |
CN |
Harmonizētās sistēmas kods |
8536 5080 00
|
Montāžas metode |
DIN sliede |
Funkcija |
Daudzfunkcionāls |
Iebūvētais augstums |
58 mm |
Uzbudinājuma veids |
Analogs ar vairākām funkcijām |
Platums moduļu atstarpju skaitā |
1 |
Pārslēgšanas slēdžu skaits |
0 |
Vadības spriegums 1 |
230 V |
Vadības sprieguma veids 1 |
AC |
Frekvences vadības spriegums 1 |
50 Hz |
Barošanas sprieguma sprieguma veids |
AC |
Barošanas spriegums |
230 V |
1. intervāla vienība |
Minūtes/ stundas |
1. intervāls |
0.1-40 |
Nominālā pārslēgšanas strāva pie 250 V maiņstrāvas |
10 A |
Slēdža jaudas kvēlspuldzes |
1000 W |
Slēdža jaudas dienasgaismas spuldze DUO |
500 VA |
Slēdža jaudas dienasgaismas spuldze induktīva |
500 VA |
Slēdža jaudas dienasgaismas spuldze paralēli |
250 VA |
Kontaktu skaits kā parasti slēgtam kontaktam |
0 |
Kontaktu skaits kā parasti atvērtam kontaktam |
1 |
Iepakojuma informācija
Iepakojuma līmenis 1 |
4010312603147, 4010312603147 |
Iepakojuma līmenis 2 |
4010312603147 |
Iepakojuma līmenis 3 |
4010312603147 |
Lejupielādes
Apraksts
1 NO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 1000W*. Standby loss 0.4 watt only. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Control voltage 230V. Supply voltage same as control voltage. Time setting between 0.1 second and 40 hours. Functions F: RV = off delay. AV = operate delay. TI = clock generator starting with impulse. TP = clock generator starting with pause. IA = impulse controlled operate delay (e.g. automatic door opener). EW = fleeting NO contact. AW = fleeting NC contact. ARV = operate and release delay. ON = permanent ON. OFF = permanent OFF. The LED below the big rotary switch indicates the contact position while time-out is in progress. It blinks while the relay contact is open, and is continuously ON as long as the relay contact is closed. The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the timebase by the multiplier. The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10). * The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.