Reģistrējieties, lai atbloķētu savas ekskluzīvās B2B cenas un sāktu iepirkties. Reģistrējieties tagad!
MS132-16T Circuit Breaker for Primary Transformer Protection 10 ... 16 A image 1
MD01 image 2
MS132-16T Circuit Breaker for Primary Transformer Protection 10 ... 16 A image 3
MS132-16T Circuit Breaker for Primary Transformer Protection 10 ... 16 A image 4
MS132-16T Circuit Breaker for Primary Transformer Protection 10 ... 16 A thumbnail 1
MD01 thumbnail 2
MS132-16T Circuit Breaker for Primary Transformer Protection 10 ... 16 A thumbnail 3
MS132-16T Circuit Breaker for Primary Transformer Protection 10 ... 16 A thumbnail 4

MS132-16T Transformatora ķēdes pārtraucēja primārā puse, izslēgšanās klase 10,

Ir noliktavā: Nē Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Cena (bez PVN):
39,86 € par gab.
Šī cena ir spēkā līdz 24.12.24
EAN: 4013614485022
MPN: 1SAM340000R1011
Iepakojums: 1
Kaste: 40
Palete: 1280

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums MS132-16T Circuit Breaker for Primary Transformer Protection 10 ... 16 A
Zīmols ABB
Kategorijas Izlaužēji
Harmonizētās sistēmas kods 8536 2010 00
Nominālā pastāvīgā strāva Iu 16 A
Ar integrētu zemsprieguma atbrīvošanu No
Stabu skaits 3
Pārslodzes atbrīvošanas strāvas iestatījums 10-16 A
Aizsardzības pakāpe (IP) IP20
Galvenās ķēdes elektriskā pieslēguma veids Skrūvju savienojums
Vadības elementa veids Pagrieziena poga
Regulēšanas diapazons neaizkavēta īssavienojuma atbrīvošana 320 A
Ierīces uzbūve Pilnīga ierīce korpusā

Iepakojuma informācija

Iepakojuma līmenis 1 4013614485022
Iepakojuma līmenis 2 4013614487224
Iepakojuma līmenis 3 4013614485022

Lejupielādes

Apraksts

The circuit breaker for transformer protection MS132-16T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 16 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.

Piederums

Piederums
4013614320385 4013614365881