Reģistrējieties, lai atbloķētu savas ekskluzīvās B2B cenas un sāktu iepirkties. Reģistrējieties tagad!
NFB62ERT-14 250-500V50/60HZ-DC Contactor image 1
NFB62ERT-14 250-500V50/60HZ-DC Contactor image 2
NFB62ERT-14 250-500V50/60HZ-DC Contactor image 3
NFB62ERT-14 250-500V50/60HZ-DC Contactor thumbnail 1
NFB62ERT-14 250-500V50/60HZ-DC Contactor thumbnail 2
NFB62ERT-14 250-500V50/60HZ-DC Contactor thumbnail 3

NFB62ERT-14 250-500V50/60HZ-DC Contactor

Ir noliktavā: Nē Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Cena (bez PVN):
61,65 € par gab.
Šī cena ir spēkā līdz 31.12.24
EAN: 3471523106543
MPN: 1SBH137060R1462
Kaste: 1

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums NFB62ERT-14 250-500V50/60HZ-DC Contactor
Zīmols ABB
Kategorijas Modulārie slēdži
Harmonizētās sistēmas kods 8536 4900 00
Papildu kontaktu skaits kā parasti atvērts kontakts 6
Papildkontaktu skaits kā parasti slēgts kontakts 2
Nominālais vadības barošanas spriegums pie AC 50 Hz 250 V
Nominālais vadības barošanas spriegums pie AC 60 Hz 250 V
Nominālais vadības barošanas spriegums pie līdzstrāvas 250 V
Sprieguma veids iedarbināšanai AC/DC

Iepakojuma informācija

Iepakojuma līmenis 1 3471523106543

Lejupielādes

Apraksts

The NFB62ERT-14 is a contactor relay complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. It is used for switching auxiliary and control circuits. These contactor relays: • include screw terminals for connection with ring tongue ferrules. Non-detachable screw with conic washer on auxiliary terminals for a fast and secure tightening of cables with ring tongue ferrules. • improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C • meet all main general and rolling stocks standards: IEC 60947-5-1 and the shocks and vibration withstand conforming to IEC 61373 cat. 1, class B • reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2, HL3 hazard levels) in group mounting • reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation • get an electronic coil interface accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data) • include mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and are side-marked with the "Mechanically Linked" symbol • include a wide range of auxiliary contact blocks for front and side mounting.