Reģistrējieties, lai atbloķētu savas ekskluzīvās B2B cenas un sāktu iepirkties. Reģistrējieties tagad!
MD01 image 1
MD01 image 2
MD01 image 3
NFZB62ES-23 100-250V50/60HZ-DC Contactor Relay image 4
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
NFZB62ES-23 100-250V50/60HZ-DC Contactor Relay thumbnail 4

NFZB62ES-23 Hilfsschütz 100-250V 50/60Hz / DC, 6S+2Ö

Ir noliktavā: Nē Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Cena (bez PVN):
67,89 €
Šī cena ir spēkā līdz 10.01.25
EAN: 3471523109032
MPN: 1SBH136059R2362
Kaste: 1

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums NFZB62ES-23 100-250V50/60HZ-DC Contactor Relay
Zīmols ABB
Kategorijas Modulārie slēdži
Harmonizētās sistēmas kods 8536 5080 00
Montāžas metode DIN sliedes/skrūve
Interfeiss No
Papildu kontaktu skaits kā parasti atvērts kontakts 6
Papildkontaktu skaits kā parasti slēgts kontakts 2
Nominālā darba strāva Ti, 400 V 3 A
Piemērots manuālai darbībai No
Papildkontaktu skaits kā pārslēgšanas kontakts 0
Ar LED indikāciju No
Savienojuma veida palīgķēde Atsperes skavas savienojums
Papildkontaktu skaits kā parasti slēgts kontakts, aizkavēta pārslēgšana 0
Papildu kontaktu skaits kā parasti atvērts kontakts, vadošais 0
Sprieguma veids iedarbināšanai AC/DC

Iepakojuma informācija

Iepakojuma līmenis 1 3471523109032
Iepakojuma līmenis 2 3471523109032

Lejupielādes

Apraksts

NFZB..S 3-pole contactors comply with the latest railway rolling stock standards and allow installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. Improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C Meet all main rollling stocks standards: IEC 60947-4-1, IEC 60947-5-1, IEC 60077-1/-2 and applicable parts of EN 50155 standards, shocks and vibration withstand conforming to IEC 61373 cat. 1, class B. Reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2 hazard levels) in group mounting. Reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation. Electronic coil interface handling large DC voltage fluctuation voltage, including several Uc DC control voltages used for battery supply and accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data). Wide range of auxiliary contact blocks for front and side mounting.