Technical Information
Preces stāvoklis |
Jauns |
Ražotāja nosaukums |
PM5341 Meter, ethernet, up to 31st H, 256K 2DI/2DO 35 alarms, MID |
Zīmols |
Schneider Electric
|
Kategorijas |
Automātika un vadība
|
Izcelsmes valsts |
IN |
Harmonizētās sistēmas kods |
9028 3090 00
|
Montāžas metode |
Priekšējais stiprinājums |
Platums |
0 mm |
Modelis |
Mērīšanas transformators |
Augstums |
0 mm |
Sprieguma veids |
AC/DC |
Izmērītās vērtības atmiņa |
Yes |
Norāde |
Grafiskais |
Frekvences mērīšana |
Yes |
Maks. strāva (Imax) |
8.5 A |
Reaktīvā jauda |
Yes |
Precizitātes klase |
0.5 |
Harmonikas mērīšana |
Yes |
Mērīšanas diapazons |
35-690 V |
Spēka faktors |
Yes |
Efektīva jauda |
Yes |
Šķietamais spēks |
Yes |
Pakāpiena leņķis (cos phi) |
No |
Atbalsta protokols LON |
No |
Modbus atbalsta protokols |
Yes |
Maks. vērtību glabāšana |
Yes |
Min. vērtību glabāšana |
Yes |
Ar sakaru interfeisu RS-485 |
No |
Kalibrēts |
No |
Impulsu izvade |
Optika |
Pole tips |
Trīs vadi/četri vadi |
Mērījumu veida slodzes profils |
Yes |
Nominālā strāva (in) |
5 A |
Ar komunikācijas interfeisu KNX |
No |
Ar sakaru interfeisu saskaņā ar EN 62056-21 |
No |
Ar sakaru saskarni M-Bus |
No |
Iepakojuma informācija
Iepakojuma līmenis 1 |
3606480614057 |
Iepakojuma līmenis 2 |
3606480614055 |
Lejupielādes
Apraksts
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display and carries additional MID certification for revenue applications. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 31st Harmonic. Include 256 kiloBytes of memory for two fixed parameters, active and reactive energy. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol are Modbus TCP/IP and BACnet/IP based on 10/100 Mbit/s, Ethernet with RJ45 port support. The meter also has two digital inputs or digital outputs, configurable, and dual relay outputs. There are 35 configurable alarms and it supports four tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 15.2 onces (430 g).