Reģistrējieties, lai atbloķētu savas ekskluzīvās B2B cenas un sāktu iepirkties. Reģistrējieties tagad!
SAFE COMMUNICATIONS EXP. 2 W SPRING TERM image 1

SAFE COMMUNICATIONS EXP. 2 W SPRING TERM

Ir noliktavā: Nē Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Cena (bez PVN):
205,92 €
Šī cena ir spēkā līdz 24.12.24
EAN: 3606480748516
MPN: XPSMCMCO0000S2G
Iepakojums: 1

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums SAFE COMMUNICATIONS EXP. 2 W SPRING TERM
Zīmols Schneider Electric
Kategorijas Programmējamie loģiskie kontrolieri
Izcelsmes valsts IT
Platums 22.5 mm
Augstums 99 mm
Dziļums 114.5 mm
Piemērots drošības funkcijām Yes
Atbalsta protokols LON No
Rūpniecisko Ethernet interfeisu skaits 0
HW interfeisu skaits RS-232 0
HW interfeisu skaits RS-422 0
HW interfeisu skaits RS-485 1
HW interfeisu sērijas TTY skaits 0
HW interfeisu skaits USB 0
Paralēlo HW interfeisu skaits 0
Citu HW interfeisu skaits 0
Ar optisko interfeisu No
Atbalsta protokols TCP/IP No
Atbalsta protokols ASI No
PROFIBUS atbalsta protokols No
Atbalsta protokols CAN No
INTERBUS atbalsta protokols No
KNX atbalsta protokols No
Modbus atbalsta protokols No
Atbalsta protokols Data-Highway No
Atbalsta protokols DeviceNet No
SUCONET atbalsta protokols No
Atbalsta protokols citām kopņu sistēmām Yes
Atlaišana No
Pārraides ātrums 2000 kBit/s
Ar iespējamu atdalīšanu No
Sprādziendrošības kategorija gāzei Nav
Eksplozijas drošības kategorija putekļiem Nav
Papildu darbības aģents (ex ia) No
Papildu darbības aģents (Ex ib) No
SERCOS atbalsta protokols No
INTERBUS drošības atbalsta protokols No
PROFINET saskarņu skaits 0
Bezvadu HW interfeisu skaits 0
Radio standarta Bluetooth No
Radio standarta Wi-Fi 802.11 No
IO saišu meistars No
Veiktspējas līmenis saskaņā ar EN ISO 13849-1 e līmenis
Atbalsta protokols AS-interfeisa drošībai darbā No
DeviceNet Safety atbalsta protokols No
Atbalsta protokols EtherNet/IP No
Atbalsta protokols Foundation Fieldbus No
PROFINET CBA atbalsta protokols No
PROFINET IO atbalsta protokols No
PROFIsafe atbalsta protokols No
Atbalsta protokols SafetyBUS lpp No
Datu pārraides veids Sērijas
Radio standarta GPRS No
Radio standarts GSM No
Radio standarts UMTS No
SIL saskaņā ar IEC 61508 3

Iepakojuma informācija

Iepakojuma līmenis 1 3606480748516

Apraksts

This Modicon MCM safe RS485 bus expansion module for remote extension has 2-channel transmitter/receiver network connection and is fitted with captive spring clamp terminals. It enables the connection of modular safety controllers type XPSMCMCP0802 and XPSMCMC10804 with the expansion modules placed at distances up to 50m (164ft.) using RS485 shielded cables. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. Combined with safe RS485 bus expansion module type XPSMCMCO0000S2, It allows to create up to 6 decentralized I/O islands. This module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors). This safe bus expansion module is connected to other I/O modules via the backplane expansion connector, and uses a RS485 serial interface shielded cable to connect to safe RS485 bus expansion module and create decentralized I/O islands. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring up to five decentralized safety related islands with a distance of 50 meters (164.04 ft) between each island on a single Safety controller CPU. Embedding a safe communication between decentralized I/O’s. The safe RS485 bus expansion module Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe RS485 bus expansion module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.