Technical Information
Preces stāvoklis |
Jauns |
Ražotāja nosaukums |
swit.act. 4-g 16 A man.act. + C-load KNX DRA |
Zīmols |
Gira
|
Kategorijas |
Sensori
|
Izcelsmes valsts |
DE |
Harmonizētās sistēmas kods |
8536 4900 00
|
Montāžas metode |
DRA (adapteris uz DIN sliedes) |
Nominālā strāva |
0 A |
Izejas jauda |
0 W |
Nominālais darba spriegums |
NA V |
Autobusu sistēma KNX |
Yes |
Autobusu sistēmas radio bieži |
No |
Autobusu sistēma Powernet |
No |
Maks. pārslēgšanas jauda |
0 W |
Ar autobusa savienojumu |
Yes |
Maks. pārslēgšanas kontaktu skaits |
4 |
Digitālo ieeju skaits |
NA |
Platums moduļu atstarpju skaitā |
4 |
Maks. pārslēgšanas strāva |
0 A |
Citas autobusu sistēmas |
Nav |
Autobusu sistēma LON |
No |
Piemērots C-slodzei |
Yes |
Savienojamas dažādas fāzes |
- |
Vietējā darbība/rokas darbība |
Yes |
Aizsardzības pakāpe (IP) |
IP20 |
Ar LED indikāciju |
No |
Moduļu paplašināšana |
- |
Autobusu sistēma KNX radio |
No |
Radio bieži divvirzienu |
- |
Autobusa modulis noņemams |
- |
Min. iebūvētās instalācijas kastes dziļums |
0 mm |
Maks. pārslēgšanas jaudas LED |
NA W |
Iepakojuma informācija
Iepakojuma līmenis 1 |
4010337042266 |
Apraksts
Switching actuator, 4-gang 16 A with manual actuation and current measurement for C-loads, for KNX DRA plus DRA switching actuators with integrated bus coupler. For switching independently controllable groups of loads. With manual switch for switching over the relay (On Off) parallel or without KNX operation. Multi-phase connection. No additional power supply required. Features: Manual actuation of the relay independent of the bus or switching position indication. NO contact or NC contact operation. Central switching function. Group feedback for reduction of bus load. Active or passive (object can be read out) cyclical feedback function. Feedback can be delayed until after the recovery of bus voltage. Logical linking function for each output. Block function can be parameterised for each channel. As an alternative, forced setting function for each output. Time functions (switch-on off delay, staircase light function – also with advance warning function). Integration in light scenes is possible, eight internal scenes at the most can be parameterised per channel. Memory function for light scenes. Elapsed operating time meter as forward backward counter with limit function (limit can be changed via bus) can be activated for each output. Input monitoring for cyclical updating with safety setting. Reactions in case of bus voltage failure and restoration can be set for each channel following an ETS programming process. The switching contacts of the switching actuator, 4-gang, C-load are especially designed for loads with a capacitive character, and therefore conditional, brief, high switch-on currents (see Technical Data). The switching actuator has an integrated current detection. A current measurement can be carried out for each channel. Independent switching of the four outputs. Current detection: Measurement of load current for each channel. Threshold values for load monitoring (e.g. signalling of load failure). Notes : Installation on DIN top-hat rail. VDE approval in accordance with EN 60669-1, EN 60669-2-1.