Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums TF42-4.2B Thermal Overload Relay 3.1 ... 4.2 A
Zīmols ABB
Kategorijas Modulārie slēdži
Harmonizētās sistēmas kods 8536 4900 00
Montāžas metode Tiešā piestiprināšana
Papildu kontaktu skaits kā parasti atvērts kontakts 1
Papildkontaktu skaits kā parasti slēgts kontakts 1
Papildkontaktu skaits kā pārslēgšanas kontakts 1
Atbrīvošanas klase KLASE 10
Galvenās ķēdes elektriskā pieslēguma veids Skrūvju savienojums
Maks. nominālais darba spriegums Ue 690 V
Regulējams strāvas diapazons 3.1-4.2 A
Atiestatīt funkcijas ievadi No
Automātiska atiestatīšanas funkcija Yes
Atiestatīšanas funkcijas spiedpoga Yes

Iepakojuma informācija

Iepakojuma līmenis 1 4013614517136
Iepakojuma līmenis 2 4013614517518

Lejupielādes

Apraksts

The TF42-B thermal overload relays are economic electromechanical protection devices for the main circuit, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98). – Manual or automatic reset selectable – Phase loss sensitive acc. to IEC/EN 60947-4-1 – TEST and STOP function – Trip indication on the front – Temperature compensation – Suitable for three- and single-phase applications – designed in accordance to the applicable parts of IEC 60077 standard – shocks and vibration withstand conforming to IEC 61373 (category 1, class B) – usable according to European fire and smoke safety standard EN 45545-2

Piederums

Piederums

Piederums
4013614527449
Piederums
3471523125018 3471523125025 3471523124325 3471523125032 3471523124332 3471523124714 3471523124721 3471523124738 3471523125117 3471523125124 3471523124219 3471523125131 3471523124226 3471523124233 3471523123519 3471523124417 3471523124424 3471523124431 3471523124813 3471523124820 3471523124837 3471523123717 3471523123724 3471523123830 3471523123731 3471523124011 3471523123915 3471523124028 3471523123922 3471523124035 3471523123939 3471523124516 3471523124523 3471523124530 3471523124912 3471523124929 3471523124936 3471523123526 3471523123618 3471523123816 3471523123823 3471523134713 3471523134829 3471523134812 3471523134720 3471523134140 3471523134737 3471523134836 3471523134041 3471523135017 3471523134911 3471523135024 3471523134928 3471523135031 3471523134935 3471523134348 3471523134249 3471523128828 3471523129719