Staircase time switch, noiseless, solid-state relay 400W image 1

Staircase time switch, noiseless, solid-state relay 400W

Noliktavas cena (bez PVN):
43,54 €
Šī cena ir spēkā līdz 2024-12-31
Cena par m: 43,54 €
EAN: 4010312401460
MPN: 23100831
Mūsu noliktava: Piegādātāja krājumi:
Vienā iepakojumā: 1 Vienā kastē: 1 Vienā paletē: N/A
Tehniskie dati
Preces stāvoklis Jauns
Ražotāja nosaukums Staircase time switch, noiseless, solid-state relay 400W
Zīmols ELTAKO
Kategorijas Releji
Izcelsmes valsts CN
Harmonizētās sistēmas kods 8536 5080 00
Montāžas metode DIN sliede
Funkcija Elektronisks ar izslēgšanas brīdinājuma signālu
Iebūvēts dziļums 58 mm
Atbrīvošana-aizkavēšanās 12-1 min
Platums moduļu atstarpju skaitā 1
Vadības spriegums 1 230 V
Vadības spriegums 2 8-230 V
Vadības sprieguma veids 1 AC
Vadības sprieguma veids 2 AC/DC
Frekvences vadības spriegums 1 50 Hz
Elektroinstalācijas sistēma 3 un 4 vadu konfigurācija
Iepriekšējs brīdinājums par izslēgšanos Mirgošana
Atkārtojas Atkārtota + nepārtraukta gaisma + laika pagarinājums
Barošanas sprieguma sprieguma veids AC
Barošanas spriegums 230 V
Maks. kvēlspuldžu slodze 400 W
Maks. slodzes dienasgaismas spuldze (paralēli kompensēta) 400 VA
Nominālā slēdža strāva 1.6 A
Spiedpogas kvēlspuldzes strāva 50 mA
Atlasāma strāvas pārsprieguma funkcija Yes
Kontaktu skaits kā parasti atvērtam kontaktam 1
Maks. pārslēgšanas jaudas LED 400 W
Iepakojuma informācija
Iepakojuma līmenis 1 4010312401460, 4010312401460
Iepakojuma līmenis 2 4010312401460
Iepakojuma līmenis 3 4010312401460
Downloads
Apraksts
Noiseless solid-state relay not potential-free. 230V LED lamps and energy saving lamps ESL up to 400W, incandescent lamps up to 400W. Switch-off early warning and pushbutton permanent light switchable. Standby loss 0.4 watt only. With ESL optimisation and multifunction. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Zero passage switching to protect lamps. The noiseless electronics and zero passage switching do not even bother the sensitive ear – unlike many synchronous motors with mechanical gears. Control, supply and switching voltage 230V. Additionally 8 to 230V UC electrically isolated universal control voltage. 3-wire and 4-wire circuits, resettable, with attic lighting if 4-wire circuit. Automatic detection of the method of connection. Glow lamp current up to 50mA, dependent on the ignition voltage of the glow lamps. Precise variable time range from 1 to 30 minutes, settable by minute scale. Permanent light switch with the big rotary switch. If the function TLZ is set, the lighting is switched on again after a power failure provided the set time has not yet elapsed. With double connections for pushbutton and lamp in order to connect either above or below or only below. If switch-off early warning function is switched on the light starts flickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals. If pushbutton permanent light is switched on permanent light can be switched on by pressing pushbutton longer than 1 second. This is switched off automatically after 60 minutes or by pressing pushbutton longer than 2 seconds. If both switch-off early warning function and permanent light pushbutton are switched on, the switch-off early warning function is activated before the permanent light switches off. When energy saving lamps ESL are completely or partially switched, then set the switch-off early warning and the pushbutton permanent light on the right hand side of the rotary switch. If the function TLZ is selected the time can be extended within the first second after switching on or resetting by pressing the pushbutton repeatedly up to three times (incrementing). Each momentary-contact control increments the set time once. With multifunction: the following functions can be selected optionally: ES (impulse switch), ER (relay), ESV (impulse switch with release delay). If the function ESV is set the time ranges (t) which can be set with the middle rotary switch are as follows: 1 = 2min, 2 = 5min, 3 = 10min, 4 = 15min, 6 = 25min, 8 = 35min, 10 = 45min, 12 = 60min, 20 = 90min, 30 = 120min. In this function the impulse switch automatically disconnects after the set delay is timed out, if a manual OFF command has not been given. Switch-off early warning and pushbutton permanent light can be switched on additionally in this position as well. Forgotten permanent light is switched off after 2 hours.