Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums Contactor, 3 pole, 380 V 400 V 22 kW, RDC 24: 24 - 27 V DC, DC operation, Spring-loaded terminals
Zīmols EATON
Kategorijas Modulārie slēdži
Izcelsmes valsts RO
Harmonizētās sistēmas kods 8536 4900 00
Moduļu versija No
Nominālā darbības jauda pie AC-3, 400 V 22 kW
Parasti atvērto kontaktu skaits kā galvenais kontakts 3
Parasti slēgto kontaktu skaits kā galvenais kontakts 0
Papildu kontaktu skaits kā parasti atvērts kontakts 0
Papildkontaktu skaits kā parasti slēgts kontakts 0
Nominālā darba strāva Ti pie AC-3, 400 V 50 A
Nominālā darba strāva Ti pie AC-1, 400 V 80 A
Nominālais vadības barošanas spriegums pie AC 50 Hz 0 V
Nominālais vadības barošanas spriegums pie AC 60 Hz 0 V
Nominālais vadības barošanas spriegums pie līdzstrāvas 24-27 V
Galvenās ķēdes elektriskā pieslēguma veids Atsperes skavas savienojums
Sprieguma veids iedarbināšanai DC
Nominālā darba strāva Ti pie AC-4, 400 V 21 A
Nominālā darbības jauda pie AC-4, 400 V 10 kW
Nominālā darbības jauda NEMA 29.8 kW

Iepakojuma informācija

Iepakojuma līmenis 1 4015081879465

Apraksts

Contactor, Application: Contactors for Motors, Contactors up to 170 A, 3 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Spring-loaded terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Spring-cage terminals on auxiliary and control circuit terminals, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 50 A , Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 80 A, enclosed: Ith= 58 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 162 A, enclosed: Ith= 145 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 15.5 kW, 380 V 400 V: P= 22 kW, 660 V 690 V: P= 30 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 6 kW, 380 V 400 V: P= 10 kW, 660 V 690 V: P= 14 kW, Can be combined with auxiliary contact: DILM150-XHIC(V)…, DILM1000-XHIC…, Instructions: Contacts to EN 50 012., Auxiliary current, coil , and main current terminals with spring-cage connection technology., Main current connections with screw terminals., integrated suppressor circuit in actuating electronics, Voltage AC/DC: DC operation