KA4257 Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC image 5
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
KA4257 Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC thumbnail 5

KA4257 Mess- und Wandlerfeld H3/B3 vorverdrahtet mit Zählerkreuz

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
4 005,75 €
Hind kehtib kuni 24.12.24
EAN: 4011617330486
MPN: 2CPX033048R9999
Karp: 1

Technical Information

Toote seisukord Uus
Tootja nimi KA4257 Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC
Bränd ABB
Kategooriad Elektrikilbid
Harmoneeritud süsteemi kood 8537 1098 00
Värvus Hall
Laius 750 mm
Mudel 1-korruseline
Kõrgus 1050 mm
RAL-number 7035
Koos montaažiplaadiga No
Ühendusvahe 300 mm
Koos juhtmestusega Yes
Laius mooduli arvudes 36
TSG-paneele 1
Jaotusridade arv 0
Mõõtekappide arv 1
Alumine ühendusruum 5-se kogumislatiga
Kaitseaste (IP) IP2XC
Peaahela lüliti tunnusvool 250 A
Katte kuju Suletud eelstantsimisega

Pakendamise üksikasjad

Pakkimistase 1 4011617330486

Allalaadimised

Kirjeldus

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, rated current 250 A, Rated current of the assembly of switchgear and controlgear InA 222 A, in RAL 7035, dimensions in mm (H x W x D): 1050 x 750 x 160, Earthing system TN-S, 5-pole, Number of SG spaces 1, Number of transformer meter spaces 1, Test terminals are included according wish DSO, Pre-wired according requirements DSO, voltage path 3 low voltage path switches B10/25kA overvoltage path category 3, busbar system Cu busbars 12 x 5 mm 5-pole, parting point before the current transformer Fuse switch disconnector NH1/250A, parting point after the current transformer Switch 250 A / 3-pole (M8), primary wiring Cu-Busbar 30 x 5 mm, Accessible to Cu busbar, outgoing: terminals screws to fuse disconnetor and PE+N busbar, Connection N+PE (M8), Note: In case short circuit is > 25 kA, Backup protection required for voltage path circuit. Short circuit value to be obtained from DSO. Busbar terminals should be ordered seperately, Grid unit 7 GU, Overall height 3, panel width 3, Space units 252, covers out of Plastic, Quick sealable connection, RAL 7035