Reģistrējieties, lai atbloķētu savas ekskluzīvās B2B cenas un sāktu iepirkties. Reģistrējieties tagad!
MD01 image 1
MD01 image 2
MD01 image 3
MD01 image 4
KA4257 Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC image 5
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
KA4257 Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC thumbnail 5

KA4257 Mess- und Wandlerfeld H3/B3 vorverdrahtet mit Zählerkreuz

Ir noliktavā: Nē Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Cena (bez PVN):
4 005,75 €
Šī cena ir spēkā līdz 24.12.24
EAN: 4011617330486
MPN: 2CPX033048R9999
Kaste: 1

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums KA4257 Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC
Zīmols ABB
Kategorijas Sadales paneļi
Harmonizētās sistēmas kods 8537 1098 00
Krāsa Pelēks
Platums 750 mm
Modelis 1 stāvs
Augstums 1050 mm
RAL numurs 7035
Ar montāžas plāksni No
Savienojuma telpa 300 mm
Ar elektroinstalāciju Yes
Platums moduļu atstarpju skaitā 36
TSG paneļu skaits 1
Izplatītāja rindu skaits 0
Skaitītāju skapju skaits 1
Apakšējā savienojuma vieta Ar kopņu joslu 5-polu
Aizsardzības pakāpe (IP) IP2XC
Galvenā slēdža nominālā strāva 250 A
Vāka modelis Slēgts ar iepriekšēju nostiprināšanu

Iepakojuma informācija

Iepakojuma līmenis 1 4011617330486

Lejupielādes

Apraksts

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, rated current 250 A, Rated current of the assembly of switchgear and controlgear InA 222 A, in RAL 7035, dimensions in mm (H x W x D): 1050 x 750 x 160, Earthing system TN-S, 5-pole, Number of SG spaces 1, Number of transformer meter spaces 1, Test terminals are included according wish DSO, Pre-wired according requirements DSO, voltage path 3 low voltage path switches B10/25kA overvoltage path category 3, busbar system Cu busbars 12 x 5 mm 5-pole, parting point before the current transformer Fuse switch disconnector NH1/250A, parting point after the current transformer Switch 250 A / 3-pole (M8), primary wiring Cu-Busbar 30 x 5 mm, Accessible to Cu busbar, outgoing: terminals screws to fuse disconnetor and PE+N busbar, Connection N+PE (M8), Note: In case short circuit is > 25 kA, Backup protection required for voltage path circuit. Short circuit value to be obtained from DSO. Busbar terminals should be ordered seperately, Grid unit 7 GU, Overall height 3, panel width 3, Space units 252, covers out of Plastic, Quick sealable connection, RAL 7035