RS485 bus actuator multifunction time relay image 1

RS485 bus actuator multifunction time relay

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
45,37 €
Hind kehtib kuni 31.12.24
EAN: 4010312313787
MPN: 30014009
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi RS485 bus actuator multifunction time relay
Bränd ELTAKO
Kategooriad Andurid
Päritoluriik CN
Harmoneeritud süsteemi kood 8526 9200 00
Paigaldusviis DRA (DIN liistule)
Tunnusvool 10 A
Väljundvõimsus 2000 W
Tunnus-talitluspinge 12 V
Siinisüsteem KNX No
Raadiosageduslik siinisüsteem Yes
Siinisüsteem Powernet No
Suurim lülitusvõimsus 2000 W
Siiniühendusega Yes
Suurim lülituskontaktide arv 1
Laius mooduli arvudes 1
Suurim lülitusvool 10 A
Muud siinisüsteemid Puudub
Siinisüsteem LON No
C-koormus -
Eri faaside ühendamine No
Lokaaljuhtimine/käsijuhtimine No
Kaitseaste (IP) IP20
LED näidikuga No
Laiendusmoodulitega No
Siinisüsteem KNX radio No
Raadiosageduslik, kahesuunaline Yes
Eemaldatav siini moodul Yes
Max. switching power LED 400 W

Pakendamise üksikasjad

Pakkimistase 1 4010312313787, 4010312313787
Pakkimistase 2 4010312313787
Pakkimistase 3 4010312313787

Allalaadimised

Kirjeldus

Multifunction time relay with 10 functions, 1 CO contact potential free 10A/250V AC, 230V LED lamps up to 400W, incandescent lamps 2000 watts*, with DX technology. Bidirectional. Only 0.4 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Wireless window contacts (FTK) at opened windows with the function NO or NC can be taught-in. If a direction switch is taught-in, a function (e.g. TI) can be started using the top switch (START) and stopped with the bottom switch (STOP). Patented Eltako Duplex technology allows you to switch normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and L to K(L). This results in an additional standby consumption of only 0.1 watt. If supply voltage fails, the two contacts switch off. When power is restored, contact 1 closes. Time setting between 0.5 second and 10 hours. Teach-in takes place using the top and middle rotary switches and then the time is set. T is the time base and xT the multiplier. The function is selected using the bottom rotary switch: RV = off delay. AV = operate delay. TI = clock generator starting with impulse. TP = clock generator starting with pause. IA = impulse controlled operate delay (e.g. automatic door opener). EW = fleeting NO contact. AW = fleeting NC contact. ARV = operate and release delay. ON = Permanent ON. OFF = Permanent OFF. The LED below the upper function rotary switch performs during the teach-in process according to the operating instructions. It shows control commands by short flickering during operation. *The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.