Technical Information
Toote seisukord |
Uus |
Tootja nimi |
Self-learning mains disconnection relay, 1 NO contact 10A |
Bränd |
ELTAKO
|
Kategooriad |
Releed
|
Päritoluriik |
CN |
Harmoneeritud süsteemi kood |
8536 5080 00
|
Paigaldusviis |
Muul viisil |
Sisseehitussügavus |
26 mm |
Tunnusvool |
10 A |
Tunnuspinge |
250 V |
Nimisagedus |
50 Hz |
Laius mooduli arvudes |
0 |
Aktiveerimise lävivool |
20 mA |
Suurim lülitusvool (cos phi = 0.6) |
10 A |
Suurim hõõglampide koormus |
1000 W |
Suurim luminofoorlampide koormus |
1000 VA |
Suurim luminofoorlampide koormus (kaks ahelat) |
1000 VA |
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) |
500 VA |
Kaitseaste (IP) |
IP20 |
Jälgitav pinge |
DC |
Pakendamise üksikasjad
Pakkimistase 1 |
4010312203477, 4010312203477 |
Pakkimistase 2 |
4010312203477 |
Pakkimistase 3 |
4010312203477 |
Allalaadimised
Kirjeldus
1 NO contact not potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load 1000W. Standby loss 0.8 watt only. Built-in device for installation. 45mm long, 45mm wide, 26mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR61-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 20mA are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit. It is learned by the FR61. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage of 230V DC with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection relay connects the phase. If the phase is switched on for the first time and after a power failure the FR61 automatically learns in again: At first an inrush current of 30mA is specified. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. This learn-in mode can be realised immediately after connection of the new load by briefly switching off the MCB.