Self-learning mains disconnection relay, 1 NO contact 10A image 1

Self-learning mains disconnection relay, 1 NO contact 10A

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
47,79 €
This price is valid until 06.01.25
EAN: 4010312203477
MPN: 61100530
Package: 1

Technical Information

Item condition New
Manufacture name Self-learning mains disconnection relay, 1 NO contact 10A
Brand ELTAKO
Categories Relays
Country of origin CN
Harmonized System Code 8536 5080 00
Mounting method Other
Built-in depth 26 mm
Rated current 10 A
Rated voltage 250 V
Rated frequency 50 Hz
Width in number of modular spacings 0
Engaging threshold current 20 mA
Max. switching current (cos phi = 0.6) 10 A
Max. incandescent lamp load 1000 W
Max. load fluorescent lamp 1000 VA
Max. load fluorescent lamp (Duo circuit) 1000 VA
Max. load fluorescent lamp (parallel compensated) 500 VA
Degree of protection (IP) IP20
Monitoring voltage DC

Packing details

Packing level 1 4010312203477, 4010312203477
Packing level 2 4010312203477
Packing level 3 4010312203477

Downloads

Description

1 NO contact not potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load 1000W. Standby loss 0.8 watt only. Built-in device for installation. 45mm long, 45mm wide, 26mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR61-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 20mA are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit. It is learned by the FR61. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage of 230V DC with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection relay connects the phase. If the phase is switched on for the first time and after a power failure the FR61 automatically learns in again: At first an inrush current of 30mA is specified. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. This learn-in mode can be realised immediately after connection of the new load by briefly switching off the MCB.