Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 1
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 2
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 3
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 1
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 2
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 3

MS132-25T Circuit Breaker for Primary Transformer Protection

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
33,20 € tk kohta
Hind kehtib kuni 01.01.25
EAN: 4013614535116
MPN: 1SAM340010R1001
Pakend: 1
Karp: 28

Technical Information

Toote seisukord Uus
Tootja nimi MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A
Bränd ABB
Kategooriad Kaitselülitid
Harmoneeritud süsteemi kood 8536 2010 00
Nominaalne püsivool Iu 0.16 A
Sisseehitatud alapingevabastiga No
Pooluste arv 3
Liigkoormuskaitse sättepiirkond 0.1-0.16 A
Kaitseaste (IP) IP20
Peaahela ühendusviis Vedruklamber ühendus
Juhtelemendi liik Pöördlüliti (pöördnupp)
Viivituseta lühisvabasti seadistuspiirkond 3.2 A
Seadme ehitus Komplektne seade korpuses

Pakendamise üksikasjad

Pakkimistase 1 4013614535116
Pakkimistase 2 4013614535420

Allalaadimised

Kirjeldus

The circuit breaker for transformer protection MS132-0.16KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.16 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.