Reģistrējieties, lai atbloķētu savas ekskluzīvās B2B cenas un sāktu iepirkties. Reģistrējieties tagad!
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 1
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 2
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 3
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 1
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 2
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 3

MS132-25T Circuit Breaker for Primary Transformer Protection

Ir noliktavā: Nē Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Cena (bez PVN):
33,20 € par gab.
Šī cena ir spēkā līdz 01.01.25
EAN: 4013614535116
MPN: 1SAM340010R1001
Iepakojums: 1
Kaste: 28

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A
Zīmols ABB
Kategorijas Izlaužēji
Harmonizētās sistēmas kods 8536 2010 00
Nominālā pastāvīgā strāva Iu 0.16 A
Ar integrētu zemsprieguma atbrīvošanu No
Stabu skaits 3
Pārslodzes atbrīvošanas strāvas iestatījums 0.1-0.16 A
Aizsardzības pakāpe (IP) IP20
Galvenās ķēdes elektriskā pieslēguma veids Atsperes skavas savienojums
Vadības elementa veids Pagrieziena poga
Regulēšanas diapazons neaizkavēta īssavienojuma atbrīvošana 3.2 A
Ierīces uzbūve Pilnīga ierīce korpusā

Iepakojuma informācija

Iepakojuma līmenis 1 4013614535116
Iepakojuma līmenis 2 4013614535420

Lejupielādes

Apraksts

The circuit breaker for transformer protection MS132-0.16KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.16 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.