Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
NFZB31ES-22 48-130V50/60HZ-DC Contactor Relay image 1
NFZB31ES-22 48-130V50/60HZ-DC Contactor Relay image 2
NFZB31ES-22 48-130V50/60HZ-DC Contactor Relay thumbnail 1
NFZB31ES-22 48-130V50/60HZ-DC Contactor Relay thumbnail 2

NFZB31ES-22 Hilfsschütz 48-130V 50/60Hz / DC, 3S+1Ö

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
57,05 €
Hind kehtib kuni 31.12.24
EAN: 3471523108820
MPN: 1SBH136059R2231
Karp: 1

Technical Information

Toote seisukord Uus
Tootja nimi NFZB31ES-22 48-130V50/60HZ-DC Contactor Relay
Bränd ABB
Kategooriad Modulaarsed lülitid
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis DIN-latt/kruvi
Liides No
Normaalselt avatud abikontaktide arv 3
Normaalselt suletud abikontaktide arv 1
Tunnus-talitlusvool Ie , 400 V 3 A
Käsitööriist No
Ümberlülituvate abikontaktide arv 0
Juhtahelate tunnus-toitepinge, AC 50 Hz 48-130 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 48-130 V
Juhtahelate tunnus-toitepinge, DC 48-130 V
LED näidikuga No
Abiabela ühendusviis Vedruklamber ühendus
Normaalselt suletud abikontaktide arv, viivitusega lülitus 0
Normaalselt avatud abikontaktide arv, leading 0
Aktiveerimispinge liik AC/DC

Pakendamise üksikasjad

Pakkimistase 1 3471523108820
Pakkimistase 2 3471523108820

Allalaadimised

Kirjeldus

NFZB..S 3-pole contactors comply with the latest railway rolling stock standards and allow installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. Improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C Meet all main rollling stocks standards: IEC 60947-4-1, IEC 60947-5-1, IEC 60077-1/-2 and applicable parts of EN 50155 standards, shocks and vibration withstand conforming to IEC 61373 cat. 1, class B. Reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2 hazard levels) in group mounting. Reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation. Electronic coil interface handling large DC voltage fluctuation voltage, including several Uc DC control voltages used for battery supply and accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data). Wide range of auxiliary contact blocks for front and side mounting.