Register to unlock your exclusive B2B prices. Register now
RS485 bus weather data gateway for multi sensor MS image 1

RS485 bus weather data gateway for multi sensor MS

Laohinnas (käibemaksuta):
50,61 €
Hind kehtib kuni 2024-12-31
Hind m kohta: 50,61 €
EAN: 4010312316887
MPN: 30014072
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 1 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi RS485 bus weather data gateway for multi sensor MS
Bränd ELTAKO
Kategooriad Andurid
Päritoluriik CN
Harmoneeritud süsteemi kood 8526 9200 00
Paigaldusviis DRA (DIN liistule)
Mudel Mitu liidest
Pinge liik DC
Võimsustarve 0.3 W
Siinisüsteem KNX No
Raadiosageduslik siinisüsteem Yes
Siinisüsteem Powernet No
Laius mooduli arvudes 1
Muud siinisüsteemid Muul viisil
Siinisüsteem LON No
Lahtimonteerimise kaitse No
Raadioliides No
Infrapunaliides No
Protokoll Muul viisil
Sõltuvalt tarnijast No
Uuendatav No
Visualiseerimine No
Veebiserver No
Talitluspinge 5 V
Kaitseaste (IP) IP20
LED näidikuga No
Siinisüsteem KNX radio No
Raadiosageduslik, kahesuunaline No
Pakendamise üksikasjad
Pakkimistase 1 4010312316887, 4010312316887
Pakkimistase 2 4010312316887
Pakkimistase 3 4010312316887
Downloads
Kirjeldus
Weather data gateway for multi sensor MS. Bidirectional. Only 0.3 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. A multisensor MS at the gateway is connected to terminals RSA and RSB. The information is received once per second and converted into bus telegrams. However, several FWG14MS can be connected to a multisensor MS e.g. to control several Eltako RS485 buses with only one MS multisensor. Only at one FWG14MS must the end resistor connected. At additional FWG14MS, this resistor must be removed. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Operation in conjunction with FAM14 or FTS14KS. The Hold terminal is connected to the FAM14 or the FTS14KS. A maximum of two FWG14MS devices can be operated in one bus. The telegram duplicator FTD14 can also send telegrams over the Wireless Building System after the IDs of the FGW14MS are taught in the FTD14 or entered using the PTC14. Receiving devices can then be FSB14, FSB61NP and FSB71. If the multisensor MS signal is not received, an alarm telegram is sent. Using the PC Tool PCT14, 96 inputs can be AND or OR linked and up to 12 outputs can be output. The BA operating mode rotary switch can be configured according to the operating instructions.