Register to unlock your exclusive B2B prices. Register now
RS485 bus weather data gateway for multi sensor MS image 1

RS485 bus weather data gateway for multi sensor MS

In stock price (excl. VAT):
50,61 €
This price is valid until 2024-12-31
Price per m: 50,61 €
EAN: 4010312316887
MPN: 30014072
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 1 Per pallet: N/A
Technical data
Item condition New
Manufacture name RS485 bus weather data gateway for multi sensor MS
Brand ELTAKO
Categories Sensors
Country of origin CN
Harmonized System Code 8526 9200 00
Mounting method DRA (DIN-rail adapter)
Model Multiple interface
Voltage type DC
Power consumption 0.3 W
Bus system KNX No
Bus system radio frequent Yes
Bus system Powernet No
Width in number of modular spacings 1
Other bus systems Other
Bus system LON No
Demounting protection No
Radio interface No
IR interface No
Protocol Other
Provider dependent No
Updateable No
Visualization No
Web-Server No
Operating voltage 5 V
Degree of protection (IP) IP20
With LED indication No
Bus system KNX radio No
Radio frequent bidirectional No
Packing details
Packing level 1 4010312316887, 4010312316887
Packing level 2 4010312316887
Packing level 3 4010312316887
Downloads
Description
Weather data gateway for multi sensor MS. Bidirectional. Only 0.3 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. A multisensor MS at the gateway is connected to terminals RSA and RSB. The information is received once per second and converted into bus telegrams. However, several FWG14MS can be connected to a multisensor MS e.g. to control several Eltako RS485 buses with only one MS multisensor. Only at one FWG14MS must the end resistor connected. At additional FWG14MS, this resistor must be removed. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Operation in conjunction with FAM14 or FTS14KS. The Hold terminal is connected to the FAM14 or the FTS14KS. A maximum of two FWG14MS devices can be operated in one bus. The telegram duplicator FTD14 can also send telegrams over the Wireless Building System after the IDs of the FGW14MS are taught in the FTD14 or entered using the PTC14. Receiving devices can then be FSB14, FSB61NP and FSB71. If the multisensor MS signal is not received, an alarm telegram is sent. Using the PC Tool PCT14, 96 inputs can be AND or OR linked and up to 12 outputs can be output. The BA operating mode rotary switch can be configured according to the operating instructions.