Technical Information
Item condition |
New |
Manufacture name |
Two-way three-phase meter, MID calibrated |
Brand |
ELTAKO
|
Categories |
Electric meters
|
Country of origin |
CN |
Harmonized System Code |
9028 3019 00
|
Mounting method |
DRA (DIN-rail adapter) |
Width |
70 mm |
Height |
82 mm |
Depth |
58 mm |
Frequency |
50 Hz |
Max. current (Imax) |
80 A |
Width in number of modular spacings |
4 |
Degree of protection (IP) |
IP20 |
Pulse rate |
1000 Imp/kWh (kvarh) |
Pole type |
Four conductor |
Nominal voltage (Un) N-L |
230 V |
Nominal current (In) |
10 A |
Packing details
Packing level 1 |
4010312501870, 4010312501870 |
Packing level 2 |
4010312501870 |
Other Technical data
Model |
Direct measurement |
Suitable for |
Purchase |
Type of indication |
Digital |
Number of positions total (counter) |
7 |
Type of meter |
Electronic |
Type of interface |
Other |
Energy type |
Effective power |
Tariff type |
Two-tariff |
Tariff control |
External |
Escapement mechanism |
- |
Calibrated |
Yes |
Approval |
Measuring Instruments Directive |
Pulse output |
Optic |
Pulse type |
S0 |
Accuracy class |
B |
Measurement type load profile |
- |
EEC40 signature |
- |
With lock code |
- |
Nominal voltage (Un) L-L |
400 V |
Downloads
Description
Two-way three-phase meter. Maximum current 3x80A. Standby loss 0.5 watt per path only. Modulair device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface as standard. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. The active energy is added depending on the sign. Positive power in the meter means energy consumption, negative power means energy delivery. The energy measurement is balanced. If the energy consumption (P positive) is greater than the energy supply (P negative), the meter reading T arrow right is increased. If the energy supply is greater than the energy consumption, the meter reading T arrow left is increased. Energy consumption is shown with a right arrow and energy supply is shown with a left arrow above the active bar in the display. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. Energy consumption and energy supply values are stored in non-volatile memory and are displayed again immediately after a power failure. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu. First the background lighting switches on. Then the total active energy per consumption and delivery, the active energy of the resettable memory consumption and delivery as well as the instantaneous power, voltage and current values for each phase conductor can be displayed. Error message: If a phase connection is missing, the corresponding phase is shown on the display.