Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
Self-learning mains disconnection relay, 1 NO contact 16A image 1

Self-learning mains disconnection relay, 1 NO contact 16A

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
51,08 €
Hind kehtib kuni 24.12.24
EAN: 4010312203255
MPN: 22100231
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi Self-learning mains disconnection relay, 1 NO contact 16A
Bränd ELTAKO
Kategooriad Releed
Päritoluriik CN
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis DIN liist
Sisseehitussügavus 26 mm
Tunnusvool 10 A
Tunnuspinge 230 V
Nimisagedus 50 Hz
Laius mooduli arvudes 3
Aktiveerimise lävivool 20 mA
Suurim lülitusvool (cos phi = 0.6) 16 A
Suurim hõõglampide koormus 2300 W
Suurim luminofoorlampide koormus 500 VA
Suurim luminofoorlampide koormus (kaks ahelat) 1000 VA
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) 500 VA
Kaitseaste (IP) IP20
Jälgitav pinge DC

Pakendamise üksikasjad

Pakkimistase 1 4010312203255, 4010312203255
Pakkimistase 2 4010312203255
Pakkimistase 3 4010312203255

Allalaadimised

Kirjeldus

1 NO contact not potential free 16A/250V AC. Self-learning. 230V LED lamps up to 200W, incandescent lamp load 2300W. Standby loss 0.8 watt only. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide and 58mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR12-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 200mA, are acceptable and, once major loads are disconnected, they do not prevent field disconnection. The limit is taught-in automatically by the FR12 using a patented method so you need not set the limit manually. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection switch connects the monitored phase after approx. 1 sec and the LED lights red.