Self-learning mains disconnection relay, 1 NO contact 16A image 1

Self-learning mains disconnection relay, 1 NO contact 16A

Ir noliktavā: Nē Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Cena (bez PVN):
51,08 €
Šī cena ir spēkā līdz 24.12.24
EAN: 4010312203255
MPN: 22100231
Iepakojums: 1

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums Self-learning mains disconnection relay, 1 NO contact 16A
Zīmols ELTAKO
Kategorijas Releji
Izcelsmes valsts CN
Harmonizētās sistēmas kods 8536 5080 00
Montāžas metode DIN sliede
Iebūvēts dziļums 26 mm
Nominālā strāva 10 A
Nominālais spriegums 230 V
Nominālā frekvence 50 Hz
Platums moduļu atstarpju skaitā 3
Ieslēgšanās sliekšņa strāva 20 mA
Maks. pārslēgšanas strāva (cos phi = 0,6) 16 A
Maks. kvēlspuldžu slodze 2300 W
Maks. slodzes dienasgaismas spuldze 500 VA
Maks. slodzes dienasgaismas spuldze (Duo ķēde) 1000 VA
Maks. slodzes dienasgaismas spuldze (paralēli kompensēta) 500 VA
Aizsardzības pakāpe (IP) IP20
Uzraudzības spriegums DC

Iepakojuma informācija

Iepakojuma līmenis 1 4010312203255, 4010312203255
Iepakojuma līmenis 2 4010312203255
Iepakojuma līmenis 3 4010312203255

Lejupielādes

Apraksts

1 NO contact not potential free 16A/250V AC. Self-learning. 230V LED lamps up to 200W, incandescent lamp load 2300W. Standby loss 0.8 watt only. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide and 58mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR12-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 200mA, are acceptable and, once major loads are disconnected, they do not prevent field disconnection. The limit is taught-in automatically by the FR12 using a patented method so you need not set the limit manually. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection switch connects the monitored phase after approx. 1 sec and the LED lights red.