Self-learning mains disconnection relay, 1 NO contact 16A image 1

Self-learning mains disconnection relay, 1 NO contact 16A

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
51,08 €
This price is valid until 24.12.24
EAN: 4010312203255
MPN: 22100231
Package: 1

Technical Information

Item condition New
Manufacture name Self-learning mains disconnection relay, 1 NO contact 16A
Brand ELTAKO
Categories Relays
Country of origin CN
Harmonized System Code 8536 5080 00
Mounting method DIN rail
Built-in depth 26 mm
Rated current 10 A
Rated voltage 230 V
Rated frequency 50 Hz
Width in number of modular spacings 3
Engaging threshold current 20 mA
Max. switching current (cos phi = 0.6) 16 A
Max. incandescent lamp load 2300 W
Max. load fluorescent lamp 500 VA
Max. load fluorescent lamp (Duo circuit) 1000 VA
Max. load fluorescent lamp (parallel compensated) 500 VA
Degree of protection (IP) IP20
Monitoring voltage DC

Packing details

Packing level 1 4010312203255, 4010312203255
Packing level 2 4010312203255
Packing level 3 4010312203255

Downloads

Description

1 NO contact not potential free 16A/250V AC. Self-learning. 230V LED lamps up to 200W, incandescent lamp load 2300W. Standby loss 0.8 watt only. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide and 58mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR12-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 200mA, are acceptable and, once major loads are disconnected, they do not prevent field disconnection. The limit is taught-in automatically by the FR12 using a patented method so you need not set the limit manually. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection switch connects the monitored phase after approx. 1 sec and the LED lights red.