Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type image 2
Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type image 3
Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type image 4
MD01 thumbnail 1
Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type thumbnail 2
Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type thumbnail 3
Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type thumbnail 4

Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type

In stock: Yes Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
181,17 €
This price is valid until 24.12.24 or while stock lasts
EAN: 3606481157744
MPN: A9D57432
Package: 1
Box: 3

Technical Information

Item condition New
Manufacture name Acti9 iC60 RCBO - 4P - 32 A - C Curve - 6000A/6kA - 30 mA - AC type
Brand Schneider Electric
Categories Leakage protection
Country of origin
Harmonized System Code 8536 2010 00
Voltage type AC
Built-in depth 45 mm
Rated current 32 A
Rated voltage 400 V
Release characteristic C
Rated insulation voltage Ui 500 V
Rated fault current 0.03 A
Leakage current type AC
Surge current capacity 0.25 kA
Current limiting class 1
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 4
Frequency 50 Hz
Degree of protection (IP) IP20
Number of protected poles 4
Concurrently switching neutral conductor Yes
Rated short-circuit breaking capacity according to IEC 60947-2 6 kA
Connectable conductor cross section solid-core 1-35 mm²
Connectable conductor cross section multi-wired 1-25 mm²
With interlocking device No
Ambient temperature during operating -25-40 °C
Flush-mounted installation No
Number of poles (total) 4
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 0 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 0 kA

Packing details

Packing level 1 3606481157744
Packing level 2 3606481157741
Packing level 3 3606481157742

Downloads

Description

This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 4P RCBO with 4 protected poles, rated current is 32A, and operating voltage is 380VAC to 415VAC. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 280VAC to 415VAC is 6000A according to EN/IEC 61009-2-1 and 6kA according to EN/IEC 60947-2. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product color is white (RAL9003). The dimensions are (W) 72mm x (H) 86mm x (D) 78mm. The weight is 423g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.