Item condition |
New |
Manufacture name |
Cable drum Ø 355mm TPE 2x2x24AWG SF/UTP CAT5e bu UL/CSA. CM 0m |
Brand |
Murrelektronik
|
Categories |
Ethernet cable (network)
|
Country of origin |
US |
Harmonized System Code |
8544 4995 00
|
UV resistant |
Yes |
Nominal cross section conductor |
0.25 mm² |
Material core insulation |
Polyurethane (PUR) |
Core identification |
Colour |
Cable type |
SF/FTP |
Weight |
50.6 kg/km |
Flame retardant |
Other |
Drain wire |
No |
Circuit integrity |
None |
Nominal voltage U |
600 |
Stranding element |
Pairs |
Colour outer sheath |
Blue |
Category |
5E |
Diameter conductor |
1.3 mm |
Conductor material |
Copper |
Screen over stranding element |
None |
Screen over stranding |
None |
Material outer sheath |
Polyurethane (PUR) |
Characteristic impedance |
55 |
Conductor category |
Class 5 = flexible |
Armouring/reinforcement |
Braiding |
Permitted cable outer temperature during assembling/handling |
-40-80 °C |
Permitted cable outer temperature after assembling without vibration |
-40-80 °C |
Number of stranding elements |
2 |
Protective sheath |
Polyurethane (PUR) |
Number of cores |
4 |
Suitable for underground installation |
No |
Halogen free according to IEC 60754-2 |
Yes |
Cable width approx. |
6.6 |
Cable height approx. |
6.6 |
Low smoke according to IEC 61034-2 |
No |
Stranding |
Bundle |
Outer diameter approx. |
6.6 mm |
With rodent protection |
No |
Oil resistant according to IEC 60811-404 |
Yes |
Conductor surface |
Bare |
Longitudinal water blocking cable |
Yes |
Radial water blocking cable |
Yes |
Reaction-to-fire according to EN 13501-6: Class |
None |
Reaction-to-fire according to EN 13501-6: Smoke production |
None |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles |
None |
Reaction-to-fire according to EN 13501-6: Acidity |
None |
AWG size |
24 |
Min. permitted bending radius, moving application with forced guidance |
66 mm |
Min. permitted bending radius, moving application/free movement |
6 mm |
Min. permitted bending radius, stationary application/permanent installation |
33 mm |
Specification core insulation |
Polyethylene (PE) |
Specification material outer sheath |
Polyethylene (PE) |
Material reinforcement |
Copper |
Cable geometry |
Round |
Core identification according to HD 308 S2 |
Yes |
Suitable as telephone cable |
Yes |
Suitable as computer data cable |
Yes |
Suitable as signalling cable |
Yes |
Certified for shipboard application |
No |
Segregation class according to EN 50174-2 |
D |
Approved type of underground installation |
Other |
Flame retardant according to IEC 60332-1-2 |
Yes |
Flame retardant according to IEC 60332-3-21 (Cat A F/R) |
No |
Flame retardant according to IEC 60332-3-22 (Cat A) |
No |
Flame retardant according to IEC 60332-3-23 (Cat B) |
No |
Flame retardant according to IEC 60332-3-24 (Cat C) |
No |
Flame retardant according to IEC 60332-3-25 (Cat D) |
No |
Halogen free according to IEC 60754-1 |
Yes |
Halogen free according to IEC 60754-3 |
Yes |
Circuit integrity according to IEC 60331-23 |
No |
Compatible with Grade2TV according to XP-C 90-483 |
Yes |
Compatible with Grade3TV according to XP-C 90-483 |
No |