Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
CDS - single phase load-shedding contactor - 2 channels image 2
CDS - single phase load-shedding contactor - 2 channels image 3
CDS - single phase load-shedding contactor - 2 channels image 4
MD01 thumbnail 1
CDS - single phase load-shedding contactor - 2 channels thumbnail 2
CDS - single phase load-shedding contactor - 2 channels thumbnail 3
CDS - single phase load-shedding contactor - 2 channels thumbnail 4

CDS - single phase load-shedding contactor - 2 channels

In stock: No Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
156,76 €
This price is valid until 24.12.24
EAN: 3606480376863
MPN: A9C15908
Package: 1
Box: 27

Technical Information

Item condition New
Manufacture name CDS - single phase load-shedding contactor - 2 channels
Brand Schneider Electric
Categories Relays
Country of origin FR
Mounting method DIN rail
Voltage type AC
Built-in depth 67 mm
Rated voltage 230 V
Width in number of modular spacings 5
Rated current Iu 5-90 A
Just-operate current 5-90 A
Rated current (control contacts) 1 A
Electrical lifespan (control contacts) 0 c (contacts)
Max. switching power (control contacts) 0 VA
Max. time-delayed switch-off 0 ms
Max. continuous current 0 A
Max. electrical switching cycles 0 c/h
Max. switching voltage (control contacts) 250 V
Mechanical lifetime (control contacts) 0 c (contacts)
Degree of protection (IP) IP20
Number of contacts as normally closed contact 2
Number of contacts as normally open contact 0
Number of contacts as change-over contact 0

Packing details

Packing level 1 3606480376863
Packing level 2 3606480376861

Downloads

Description

This Acti9 CDS is single-phase load-shedder for 1 pole installation with 1 relay per phase. When the consumption exceeds the selected threshold, it temporarily cuts off the power supply to non-priority circuits. It increases the number of loads without modifying the installed power. The load-shedding and restoration in cascading configuration of 2 non-priority circuits via 2 relays with time-delayed action. This device reduces the installed power and prevents nuisance tripping of the upstream circuit breaker. The Iu Rated current is 5A to 90A. The Rated current (control contacts) is 1A. The Ui insulation voltage is 230VAC. The Ue operating voltage is 230VAC +/- 10%. The operating frequency is 50Hz or 60Hz. The power consumption is 12VA. The active power is 20kW maximum. The connection is done with rigid coper cables 10mm² to 50mm² or flexible or with ferrule copper cables 10mm² to 35mm². The dimensions are (W) 90mm x (H) 77mm x (D) 60mm. The width in 9mm pitches is 10. The weight is 300g. The degree of protection is IP20 and IP40 for a device in modular enclosure. The Operating temperature is -5°C to +50°C. The Storage temperature is -40°C to +70°C. It complies with NF C 61.750 and EN 500.81.1 standards.