Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 2.5 A, 3 poles 3d image 2
circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 2.5 A, 3 poles 3d image 3
circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 2.5 A, 3 poles 3d image 4
MD01 thumbnail 1
circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 2.5 A, 3 poles 3d thumbnail 2
circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 2.5 A, 3 poles 3d thumbnail 3
circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 2.5 A, 3 poles 3d thumbnail 4

circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 2.5 A, 3 poles 3d

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
Price by request
This price is valid while stock lasts
EAN: 3606480009365
MPN: LV429755
Package: 1

Technical Information

Item condition New
Manufacture name circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 2.5 A, 3 poles 3d
Brand Schneider Electric
Categories Motor protection circuit-breakers
Country of origin FR
Harmonized System Code 8536 2010 90
Width 105 mm
Height 161 mm
Depth 86 mm
Rated operation power at AC-3, 400 V 0 kW
With integrated auxiliary switch No
Rated permanent current Iu 2.5 A
With integrated under voltage release No
Number of poles 3
Rated operating voltage 690 V
Degree of protection (IP) IP40
With thermal protection No
Type of electrical connection of main circuit Screw connection
Type of control element Other
Switch off technique Magnetic
Rated operation power at AC-3, 230 V 0 kW
Rated short-circuit breaking capacity lcu at 400 V, AC 50 kA
Adjustment range undelayed short-circuit release 15-35 A
Phase failure sensitive No
Device construction Built-in device fixed built-in technique

Packing details

Packing level 1 3606480009365

Downloads

Description

This Compact NSX100N is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for motor protection applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 2.5A rating magnetic trip unit (MA). MA trip unit provides an adjustable magnetic protection for instantaneous tripping. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX100N is part of Schneider Electric EcoStruxure Power architecture.