Register to unlock your exclusive B2B prices and start shopping. Sign up now!
COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 45 - 3P CURVE C 6A TYPE A Idn=0,3A - 3 MODULES image 1
COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 45 - 3P CURVE C 6A TYPE A Idn=0,3A - 3 MODULES image 2
COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 45 - 3P CURVE C 6A TYPE A Idn=0,3A - 3 MODULES thumbnail 1
COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 45 - 3P CURVE C 6A TYPE A Idn=0,3A - 3 MODULES thumbnail 2

COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 45 - 3P CURVE C 6A TYPE A Idn=0,3A - 3 MODULES

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
105,86 €
This price is valid until 24.12.24
EAN: 8011564060630
MPN: GW94255
Package: 1
Box: 4
Pallet: 464

Technical Information

Item condition New
Manufacture name COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 45 - 3P CURVE C 6A TYPE A Idn=0,3A - 3 MODULES
Brand GEWISS
Categories Leakage protection
Harmonized System Code 8536 2010 00
Voltage type AC
Built-in depth 72 mm
Rated current 6 A
Rated voltage 400 V
Release characteristic C
Rated insulation voltage Ui 500 V
Rated fault current 0.3 A
Leakage current type A
Surge current capacity 0.25 kA
Current limiting class 1
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 3
Frequency 50/60 Hz
Degree of protection (IP) IP20
Number of protected poles 3
Concurrently switching neutral conductor No
Rated short-circuit breaking capacity according to IEC 60947-2 4.5 kA
Connectable conductor cross section solid-core 35 mm²
Connectable conductor cross section multi-wired 35 mm²
With interlocking device No
Ambient temperature during operating -25-40 °C
Flush-mounted installation No
Number of poles (total) 3
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 4.5 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 4.5 kA

Packing details

Packing level 1 8011564060630
Packing level 2 8011564060630
Packing level 3 8011564060630

Downloads

Description

90 RCD Range Modular circuit breakers for residual current protection - The 90 RCD range meets any ground fault protection requirement for any area of application.The range comprises MDC compact residual current c.b. with overcurrent protection. (from 6 to 32 A, curves B and C, up to 10 kA and lΔn from 30 and 300 mA type AC, A, A[IR] and A[S] and F) BD and BDHP, add-on residual current devices for circuit breakers MT and MTHP (lΔn from 10 mA to 3 A type AC, A, A[IR], A[S] and A adjustable) IDP residual current circuit breakers (up to 125 A, lΔn from 10 to 500 mA type AC, A, A[IR], A[S], F, B).