Register to unlock your exclusive B2B prices. Register now
MD01 image 1
EP MVS CB 2000A 50kA 3P MDO ETA5 drawout manual Circuit breaker image 2
EP MVS CB 2000A 50kA 3P MDO ETA5 drawout manual Circuit breaker image 3
EP MVS CB 2000A 50kA 3P MDO ETA5 drawout manual Circuit breaker image 4

EP MVS CB 2000A 50kA 3P MDO ETA5 drawout manual Circuit breaker

In stock price (excl. VAT):
4 600,37 €
This price is valid until 2024-12-24
Price per m: 4 600,37 €
EAN: 3606480536540
MPN: MVS20N3MW5A
Our warehouse: No Vendor stock: No
Per package: 1 Per box: N/A
Technical data
Item condition New
Manufacture name EP MVS CB 2000A 50kA 3P MDO ETA5 drawout manual Circuit breaker
Brand Schneider Electric
Categories Breakers
Harmonized System Code 8536 2090 90
Number of auxiliary contacts as normally open contact 2
Number of auxiliary contacts as normally closed contact 2
Rated permanent current Iu 2000 A
With integrated under voltage release No
Number of poles 3
Overload release current setting 800-2000 A
Number of auxiliary contacts as change-over contact 4
Rated voltage 220-440 V
Degree of protection (IP) IP40
Position of connection for main current circuit Back side
Motor drive integrated No
Type of electrical connection of main circuit Bolt connection
Type of control element Push button
With switched-off indicator Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 50 kA
Adjustment range short-term delayed short-circuit release 1200-20000 A
Adjustment range undelayed short-circuit release 4000-30000 A
Suitable for DIN rail (top hat rail) mounting No
Integrated earth fault protection No
Motor drive optional Yes
Device construction Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional No
Complete device with protection unit Yes
Packing details
Packing level 1 3606480536540
Downloads
Description
EasyPact MVS20N is a 2000A circuit breaker. The breaking capacity (Icu) is 50kA rms at 440VAC 50/60Hz. The operational voltage is 690VAC. This version is 3 poles drawout. Electronic trip unit provides LSI protection include Overload, Short-time and Instantaneous protection. A digital LCD screen continuously displaysI1, I2, I3, IN and maximeter(Imax). Fault indications LED indicate 4 types of fault which are Ir (Overload), Isd (Short time), Ii (Instantaneous) and Ap (Internal fault). It could be manual operated without gear motor, closing release and opening release. EasyPact MVS is compliant with international standards (IEC 60947, CE, EAC and RoHS). The dimension is 439mm x 441mm x 395mm (H x W x D).