Register to unlock your exclusive B2B prices and start shopping. Sign up now!
***GV5P150F 3P 36kA Motor rcuit Breaker image 1
***GV5P150F 3P 36kA Motor rcuit Breaker image 2
***GV5P150F 3P 36kA Motor rcuit Breaker image 3
***GV5P150F 3P 36kA Motor rcuit Breaker image 4
***GV5P150F 3P 36kA Motor rcuit Breaker thumbnail 1
***GV5P150F 3P 36kA Motor rcuit Breaker thumbnail 2
***GV5P150F 3P 36kA Motor rcuit Breaker thumbnail 3
***GV5P150F 3P 36kA Motor rcuit Breaker thumbnail 4

***GV5P150F 3P 36kA Motor rcuit Breaker

In stock: No Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
221,02 €
This price is valid until 24.12.25
EAN: 3606489915407
MPN: GV5P150F
Package: 1
Box: 6

Technical Information

Item condition New
Manufacture name ***GV5P150F 3P 36kA Motor rcuit Breaker
Brand Schneider Electric
Categories Motor protection circuit-breakers
Country of origin FR
Harmonized System Code 8536 2090 90
Width 105 mm
Height 161 mm
Depth 155 mm
Rated operation power at AC-3, 400 V 75 kW
With integrated auxiliary switch No
Rated permanent current Iu 150 A
With integrated under voltage release No
Number of poles 3
Rated operating voltage 0-690 V
Overload release current setting 70-150 A
Degree of protection (IP) IP40
With thermal protection Yes
Type of electrical connection of main circuit Screw connection
Type of control element Turn button
Switch off technique Electronic
Rated operation power at AC-3, 230 V 40 kW
Rated short-circuit breaking capacity lcu at 400 V, AC 36 kA
Adjustment range undelayed short-circuit release 2250 A
Phase failure sensitive Yes
Device construction Complete device in housing

Packing details

Packing level 1 3606489915407
Packing level 2 3606489915404

Downloads

Description

TeSys GV motor circuit breaker, 3 poles (3P), 150A/690V, for protection of 3-phase motors 55-75kW@400V. It provides thermal magnetic protection and additional protections, breaking capacity Icu 36kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors). Thermal protection adjustable by dials with a setting current Ir in range 70-150A and a selectable tripping class 5, 10 or 20, magnetic protection at 15 In. Additional protections with fixed pick-up include short time delay protection Isd at 13 Ir, phase unbalance and loss protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).