Harmony analog, Temperature transmitter, 0..100 °C/32..212 °F, for Universal Pt100 probes

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
91,11 €
This price is valid until 24.12.24
EAN: 3389110108965
MPN: RMPT30BD
Package: 1
Box: 47
Pallet: 752

Technical Information

Item condition New
Manufacture name Harmony analog, Temperature transmitter, 0..100 °C/32..212 °F, for Universal Pt100 probes
Brand Schneider Electric
Categories Sensors
Country of origin ID
Mounting method Snap mounting support rail
Width 25 mm
Height 78 mm
Depth 80 mm
Switching current 0.004 A
Number of channels 1
Power consumption 1.44 W
Switching power 1.4 VA
Type of power supply Active
Operating temperature 0-60 °C
Switching voltage 24 V
Switching frequency 0 Hz
Type of electric connection Screw connection
Degree of protection (IP) IP20
Number of output ranges +10 V ... -10 V 0
Number of output ranges +5 V ... -5 V 0
Number of output ranges 0 V ... 1 V 0
Number of output ranges 0 mA ... 10 mA 0
Number of output ranges 0 V ... 10 V 1
Number of output ranges 0 mV ... 100 mV 0
Number of output ranges 0 V ... 2 V 0
Number of output ranges 0 V ... 2.5 V 0
Number of output ranges 0 mA ... 20 mA 1
Number of output ranges 0 V ... 20 V 0
Number of output ranges 0 mV ... 200 mV 0
Number of output ranges 0 V ... 24 V 0
Number of output ranges 0 V ... 30 V 0
Number of output ranges 0 mV ... 300 mV 0
Number of output ranges 0 mA ... 5 mA 0
Number of output ranges 0 V ... 5 V 0
Number of output ranges 0 mV ... 500 mV 0
Number of output ranges 0 mV ... 60 mV 0
Number of output ranges -1 V ... +1 V 0
Number of output ranges 1 V ... 5 V 0
Number of output ranges -10 mA ... +10 mA 0
Number of output ranges -10 V ... +10 V 0
Number of output ranges 10 V ... 0 V 0
Number of output ranges 10 V ... 2 V 0
Number of output ranges -100 mV ... +100 mV 0
Number of output ranges -2 V ... +2 V 0
Number of output ranges 2 V ... 10 V 0
Number of output ranges -2.5 V ... +2.5 V 0
Number of output ranges -20 mA ... +20 mA 0
Number of output ranges -20 V ... +20 V 0
Number of output ranges 20 mA ... 0 mA 0
Number of output ranges 20 mA ... 4 mA 0
Number of output ranges -300 mV ... +300 mV 0
Number of output ranges 4 mA ... 20 mA 1
Number of output ranges -5 mA ... +5 mA 0
Number of output ranges -5 V ... +5 V 0
Number of output ranges 5 V ... 0 V 0
Number of output ranges 5 V ... 1 V 0
Number of output ranges -500 mV ... +500 mV 0
Number of output ranges -60 mV ... +60 mV 0
Number of input ranges +10 V ... -10 V 0
Number of input ranges +5 V ... -5 V 0
Number of input ranges 0 V ... 1 V 0
Number of input ranges 0 mA ... 10 mA 0
Number of input ranges 0 V ... 10 V 1
Number of input ranges 0 mV ... 100 mV 0
Number of input ranges 0 V ... 2 V 0
Number of input ranges 0 V ... 2.5 V 0
Number of input ranges 0 mA ... 20 mA 1
Number of input ranges 0 V ... 20 V 0
Number of input ranges 0 mV ... 200 mV 0
Number of input ranges 0 V ... 24 V 0
Number of input ranges 0 V ... 30 V 0
Number of input ranges 0 mV ... 300 mV 0
Number of input ranges 0 mA ... 5 mA 0
Number of input ranges 0 V ... 5 V 0
Number of input ranges 0 mV ... 500 mV 0
Number of input ranges 0 mV ... 60 mV 0
Number of input ranges -1 V ... +1 V 0
Number of input ranges 1 V ... 5 V 0
Number of input ranges -10 mA ... +10 mA 0
Number of input ranges -10 V ... +10 V 0
Number of input ranges 10 V ... 0 V 0
Number of input ranges 10 V ... 2 V 0
Number of input ranges -100 mV ... +100 mV 0
Number of input ranges -2 V ... +2 V 0
Number of input ranges 2 V ... 10 V 0
Number of input ranges -2.5 V ... +2.5 V 0
Number of input ranges -20 mA ... +20 mA 0
Number of input ranges -20 V ... +20 V 0
Number of input ranges 20 mA ... 0 mA 0
Number of input ranges 20 mA ... 4 mA 0
Number of input ranges -300 mV ... +300 mV 0
Number of input ranges 4 mA ... 20 mA 1
Number of input ranges -5 mA ... +5 mA 0
Number of input ranges -5 V ... +5 V 0
Number of input ranges 5 V ... 0 V 0
Number of input ranges 5 V ... 1 V 0
Number of input ranges -500 mV ... +500 mV 0
Number of input ranges -60 mV ... +60 mV 0
Rated supply voltage at DC 24 V
Load 0.2 Ohm
Load influence 0 %/100%
Inherently safe according to EN 60947-5-6 NAMUR Yes
Galvanic separation between output to output No
Galvanic separation between input and output No
Galvanic separation between inputs No
Galvanic separation between supply voltage and all other current circuits No
Construction type of device Other
Malfunction message output No
Temperature drift 0 %/K
SIL according to IEC 61508 None

Packing details

Packing level 1 3389110108965
Packing level 2 3389110108969
Packing level 3 3389110108965

Downloads

Description

This temperature transmitter is part of the range of Harmony Analog interfaces. It is designed to convert signal of Pt100 probe into standard electrical signal which is compatible with automation platforms, controllers. Its supply voltage is 24V DC, non isolated. It also allows the connection distance between a sensor and the measurement acquisition device to be increased. The cables used to connect the converters to process equipment (PLCs) are standard cables, which are more cost effective than extension cables or compensation cables suitable for low level signals for Pt100 probes or thermocouples. Conforming to IEC standards, UL and CSA certified, this converter is suitable for universal use. 0 0 0 0 0 0 0 0 0 0 0