Item condition |
New |
Manufacture name |
I/O (input/output) application module, Enerlin'X |
Brand |
Schneider Electric
|
Categories |
Programmable logic controllers
|
Harmonized System Code |
8538 9099 99
|
Width |
71.7 mm |
Height |
116 mm |
Depth |
70.6 mm |
Input current at signal 1 |
6.1 mA |
Suitable for safety functions |
No |
Number of digital inputs |
6 |
Number of digital outputs |
3 |
Number of analogue inputs |
1 |
Number of analogue outputs |
0 |
Time delay at signal exchange |
0-20 ms |
Voltage type of supply voltage |
DC |
Supporting protocol for LON |
No |
Number of HW-interfaces industrial Ethernet |
0 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
0 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
2 |
With optical interface |
No |
Type of voltage (input voltage) |
DC |
Supporting protocol for TCP/IP |
No |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
No |
Supporting protocol for CAN |
No |
Supporting protocol for INTERBUS |
No |
Supporting protocol for KNX |
No |
Supporting protocol for Modbus |
No |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
No |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
No |
Output voltage at digital output |
250 V |
Output current at digital output |
5 A |
Analogue input, current |
No |
Analogue input, voltage |
No |
Analogue input, resistor |
No |
Analogue input, resistor temperature |
Yes |
Analogue input, thermocouple |
Yes |
Analogue input signal configurable |
Yes |
Analogue output, current |
No |
Analogue output, voltage |
No |
Analogue output signal configurable |
No |
Short-circuit protection, digital outputs available |
Yes |
Resolution of the analogue inputs |
0 Bit |
Resolution of the analogue outputs |
0 Bit |
Type of digital output |
Other |
Type of electric connection |
Screw connection |
Rail mounting possible |
Yes |
Fieldbus connection over separate bus coupler possible |
No |
System accessory |
No |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Degree of protection (IP) |
IP2X |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Number of interfaces PROFINET |
0 |
Number of HW-interfaces Wireless |
0 |
Front built-in possible |
No |
Rack-assembly possible |
No |
Wall mounting/direct mounting |
No |
Radio standard Bluetooth |
No |
Radio standard Wi-Fi 802.11 |
No |
IO link master |
Yes |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
Yes |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supply voltage DC |
19.2-26.4 V |
Permitted voltage at input |
19.8-25.2 V |
Type of output voltage |
AC |
Digital inputs configurable |
Yes |
Analogue inputs configurable |
Yes |
Analogue outputs configurable |
No |
Digital outputs configurable |
Yes |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
SIL according to IEC 61508 |
None |