Technical Information

Item condition New
Manufacture name iQuick PRD 8kA 340V 3P+N Tips 2+3
Brand Schneider Electric
Categories Lighting protection
Country of origin
Harmonized System Code 8536 3030 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 3
Construction size Other
Voltage protection level 1.2 kV
Max. continuous voltage AC 350 V
Nominal discharge surge current (8/20) 2 kA
Nominal voltage AC 400 V
Nominal voltage DC 0 V
Category type 2 Yes
Voltage protection level L-N 1.2 kV
Signalling at the device Optic
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 1.5 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 25 mm²
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 8 kA
Short-circuit breaking capacity (Isccr) 25 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Integrated short-circuit protection selective to fuse gG 0 A

Packing details

Packing level 1 3606480387128
Packing level 2 3606480387126

Description

This Acti9 iQuick PRD8r surge arrester protects 3P+N residential and larger buildings installations against indirect transient overvoltages. This Type 2 or Type 3 device autoprotected by integrated circuit-breaker is recommended for moderate risk level in secondary panel board. The surge arresters with r indication have remote transfer of the information Cartridge to be replaced. This prewired surge arrester allows quick replacement of withdrawable cartridges when they are damaged. It incorporates its end of life safety disconnector. The Isc integrated breaking capacity is 25kA. This Acti 9 iQuick PRD8r is compatible with TT and TN-S earthing system. The Imax maximum discharge current is 8kA. The In nominal discharge current is 2kA. The Uc maximum continuous operating voltage in DM differential mode (between phase and neutral) is 350VAC. The Uc maximum continuous operating voltage in CM common mode (between neutral and earth) is 264VAC. The Up Voltage protection level in DM differential mode (between neutral and earth) is below or equal to 1.2kV (Type2) or 1.4 kV (Type3). The Up Voltage protection level in CM common mode (between neutral and earth) is below 1.7kV (Type2) or 1.5kV (Type3). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 131.5mm x (H) 103.8mm x (D) 75.9mm. The width in 9mm pitches is 15. The weight is 810g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product complies with IEC/EN 60947-5-1 and EN 61643-11: 2012 and IEC 61643-11: 2011 Type 2 standards.