Register to unlock your exclusive B2B prices and start shopping. Sign up now!
LTRk-E12, 230 V AC image 1
LTRk-E12, 230 V AC image 2
LTRk-E12, 230 V AC image 3
LTRk-E12, 230 V AC thumbnail 1
LTRk-E12, 230 V AC thumbnail 2
LTRk-E12, 230 V AC thumbnail 3

LTRk-E12, 230 V AC

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
48,64 €
This price is valid until 17.01.25
EAN: 4250184121053
MPN: 1102830530
Package: 1
Box: 2

Technical Information

Item condition New
Manufacture name LTRk-E12, 230 V AC
Brand METZ CONNECT
Categories Relays
Country of origin DE
Harmonized System Code 8536 4900 00
Width 22.5 mm
Height 75 mm
Depth 100 mm
Remote operation possible No
Suitable as remote control No
Function flashing, starting with pause, fixed time No
Function flashing, starting with pulse, fixed time No
Clock function, starting with pause, variable No
Clock function, starting with pulse, variable No
With semiconductor output No
Function delay-on energization Yes
Function floating contact on energization No
Function star-delta No
Time range 1.5-30 s
Function delay on de-energization Yes
Function floating contact on de-energization No
Function pulse shaping No
Type of electric connection Screw connection
Rated control supply voltage at AC 50 Hz 230 V
Rated control supply voltage at AC 60 Hz NA V
Rated control supply voltage at DC NA V
Number of outputs, delayed, normally open contact 2
Pluggable on auxiliary contact block No
Outputs, reversible delayed/undelayed No
Suitable for DIN rail (top hat rail) mounting Yes
Voltage type for actuating AC

Packing details

Packing level 1 4250184121053
Packing level 2 4250184121053

Description

The fan timer relay was designed especially for controlling two-level motors. Response and switch-off delay can be adjusted separately and infinitely. A two-level switch is used for activation. The motor contactors are activated by two mutually blocking outputs. Mode of operation:, 1. If you directly select level 2, level 1 is first activated for the adjusted start-up time so that the fan can accelerate to nominal speed. Then level 2 is activated., 2. When switching from level 2 back to level 1 or switching off, a switch-off delay is activated allowing the fan to run down before level 1 is activated., 3. If level 1 has been activated for minimum the adjusted start-up time, it is immediately switched to level 2. When switching from level 1 to 2, the interruption may be max. 250 ms. If this time is exceeded, the procedure is as described under point 1.