Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
Miniature circuit-breaker, Acti9 NG125A, 3P, 80 A, C curve, 16 kA (IEC 60947-2) image 2
Miniature circuit-breaker, Acti9 NG125A, 3P, 80 A, C curve, 16 kA (IEC 60947-2) image 3
Miniature circuit-breaker, Acti9 NG125A, 3P, 80 A, C curve, 16 kA (IEC 60947-2) image 4
MD01 thumbnail 1
Miniature circuit-breaker, Acti9 NG125A, 3P, 80 A, C curve, 16 kA (IEC 60947-2) thumbnail 2
Miniature circuit-breaker, Acti9 NG125A, 3P, 80 A, C curve, 16 kA (IEC 60947-2) thumbnail 3
Miniature circuit-breaker, Acti9 NG125A, 3P, 80 A, C curve, 16 kA (IEC 60947-2) thumbnail 4

Miniature circuit-breaker, Acti9 NG125A, 3P, 80 A, C curve, 16 kA (IEC 60947-2)

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
135,40 €
This price is valid until 03.01.25
EAN: 3303430186038
MPN: 18603
Package: 1
Box: 18

Technical Information

Item condition New
Manufacture name Miniature circuit-breaker, Acti9 NG125A, 3P, 80 A, C curve, 16 kA (IEC 60947-2)
Brand Schneider Electric
Categories Breakers
Harmonized System Code 8536 2090 90
Voltage type AC/DC
Built-in depth 47 mm
Rated current 80 A
Rated voltage 400 V
Frequency 50-60 Hz
Release characteristic C
Rated insulation voltage Ui 690 V
Current limiting class 0
Over voltage category 4
Pollution degree 3
Width in number of modular spacings 4.5
Explosion-proof No
Degree of protection (IP) IP20
Number of protected poles 3
Concurrently switching neutral conductor No
Connectable conductor cross section solid-core 16-70 mm²
Connectable conductor cross section multi-wired 10-50 mm²
Ambient temperature during operating -30-70 °C
Flush-mounted installation No
Additional equipment possible Yes
Number of poles (total) 3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V 0 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V 0 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V 16 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V 16 kA
Rated impulse withstand voltage Uimp 8 kV

Packing details

Packing level 1 3303430186038
Packing level 2 3303430186036

Downloads

Description

This Acti9 NG125a product is a low voltage circuit breaker. It is a 3P circuit breaker with 3 protected poles and 80A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 16kA at 380VAC to 415VAC conforming to EN/IEC 60947-2 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. It is suitable for isolation in the industrial sector according to IEC/EN 60947-2 standard. The fault tripping is indicated by a red mechanical state indicator light on the front face. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is equal or below 375VDC, 220VAC to 240VAC, 380VAC to 415VAC, 440VAC or 500VAC. The Ui rated insulation voltage is 690VAC. The Uimp rated impulse withstand voltage is 8kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 9 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 81mm x (H) 103mm x (D) 81mm. The weight is 0.72kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 70°C.