Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
Miniature circuit-breaker, Acti9 NG125LMA, 2P, 80 A, MA curve, 50 kA (IEC 60947-2) image 2
Miniature circuit-breaker, Acti9 NG125LMA, 2P, 80 A, MA curve, 50 kA (IEC 60947-2) image 3
Miniature circuit-breaker, Acti9 NG125LMA, 2P, 80 A, MA curve, 50 kA (IEC 60947-2) image 4
MD01 thumbnail 1
Miniature circuit-breaker, Acti9 NG125LMA, 2P, 80 A, MA curve, 50 kA (IEC 60947-2) thumbnail 2
Miniature circuit-breaker, Acti9 NG125LMA, 2P, 80 A, MA curve, 50 kA (IEC 60947-2) thumbnail 3
Miniature circuit-breaker, Acti9 NG125LMA, 2P, 80 A, MA curve, 50 kA (IEC 60947-2) thumbnail 4

Miniature circuit-breaker, Acti9 NG125LMA, 2P, 80 A, MA curve, 50 kA (IEC 60947-2)

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
191,85 €
This price is valid until 14.02.25
EAN: 3303430188766
MPN: 18876
Package: 1
Box: 6

Technical Information

Item condition New
Manufacture name Miniature circuit-breaker, Acti9 NG125LMA, 2P, 80 A, MA curve, 50 kA (IEC 60947-2)
Brand Schneider Electric
Categories Breakers
Harmonized System Code 8536 2090 90
Voltage type AC/DC
Built-in depth 47 mm
Rated current 80 A
Rated voltage 230 V
Frequency 50-60 Hz
Release characteristic MA
Rated insulation voltage Ui 690 V
Current limiting class 0
Over voltage category 4
Pollution degree 3
Width in number of modular spacings 3
Explosion-proof No
Degree of protection (IP) IP20
Number of protected poles 2
Concurrently switching neutral conductor Yes
Connectable conductor cross section solid-core 16-70 mm²
Connectable conductor cross section multi-wired 10-50 mm²
Ambient temperature during operating -30-70 °C
Flush-mounted installation No
Additional equipment possible Yes
Number of poles (total) 2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V 0 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V 0 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V 100 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V 50 kA
Rated impulse withstand voltage Uimp 8 kV

Packing details

Packing level 1 3303430188766
Packing level 2 3303430188763
Packing level 3 3303430188764

Downloads

Description

This Acti9 NG125LMA product is a low voltage circuit breaker. It is a 2P circuit breaker with 2 protected poles and 80A In rated current and MA tripping curve. The rated short circuit breaking capacity goes up to 100kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 100kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. It is suitable for isolation in the industrial sector according to IEC/EN 60947-2 standard. The fault tripping is indicated by a red mechanical state indicator light on the front face of the circuit breaker. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is going from 380VAC to 415VAC. The Ui rated insulation voltage is 690VAC. The Uimp rated impulse withstand voltage is 8kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 6 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 54mm x (H) 103mm x (D) 81mm. The weight is 0.48kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 70°C.