Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals image 2
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals image 3
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals image 4
MD01 thumbnail 1
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals thumbnail 2
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals thumbnail 3
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals thumbnail 4

Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
109,04 €
This price is valid until 24.12.24
EAN: 3606481309853
MPN: GV4L07N6
Package: 1

Technical Information

Item condition New
Manufacture name Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals
Brand Schneider Electric
Categories Motor protection circuit-breakers
Country of origin PL
Harmonized System Code 8536 2010 90
Width 81 mm
Height 155 mm
Depth 165 mm
Rated operation power at AC-3, 400 V 3 kW
With integrated auxiliary switch No
Rated permanent current Iu 7 A
With integrated under voltage release No
Number of poles 3
Rated operating voltage 0-690 V
Degree of protection (IP) IP40
With thermal protection No
Type of electrical connection of main circuit Screw connection
Type of control element Turn button
Switch off technique Magnetic
Rated operation power at AC-3, 230 V 1.5 kW
Rated short-circuit breaking capacity lcu at 400 V, AC 50 kA
Adjustment range undelayed short-circuit release 42-98 A
Phase failure sensitive No
Device construction Complete device in housing

Packing details

Packing level 1 3606481309853

Downloads

Description

TeSys GV motor circuit breaker, 3 poles (3P), 7A/690V, for protection of 3-phase motors 1.5-3kW@400V. It provides magnetic protection, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).