Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
MD01 image 2
PM5350 Power & Energy meter with THD, alarming image 3
PM5350 Power & Energy meter with THD, alarming image 4
PM5350 Power & Energy meter with THD, alarming image 5
MD01 thumbnail 1
MD01 thumbnail 2
PM5350 Power & Energy meter with THD, alarming thumbnail 3
PM5350 Power & Energy meter with THD, alarming thumbnail 4
PM5350 Power & Energy meter with THD, alarming thumbnail 5

PM5350 Power & Energy meter with THD, alarming

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
275,12 €
This price is valid until 24.12.25
EAN: 3606480284311
MPN: METSEPM5350
Package: 1
Box: 12

Technical Information

Item condition New
Manufacture name PM5350 Power & Energy meter with THD, alarming
Brand Schneider Electric
Categories Automatics and control
Harmonized System Code 9028 3090 00
Mounting method Front mounting
Width 102 mm
Model Measurement transformer
Height 112 mm
Voltage type AC/DC
Measured value memory Yes
Indication Graphic
Frequency measurement Yes
Max. current (Imax) 8.5 A
Reactive power Yes
Accuracy class 0.5
Harmonics measurement Yes
Measuring range 35-690 V
Power factor Yes
Effective power Yes
Apparent power Yes
Step angle (cos phi) No
Supporting protocol for LON No
Supporting protocol for Modbus Yes
Max. value storage Yes
Min. value storage Yes
With communication interface RS-485 Yes
Calibrated No
Pulse output Optic
Pole type Three conductor/four conductor
Measurement type load profile Yes
Nominal current (In) 5 A
With communication interface KNX No
With communication interface according to EN 62056-21 No
Wth communication interface M-Bus No

Packing details

Packing level 1 3606480284311
Packing level 2 3606480284319

Downloads

Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. Include a non-volatile memory for several parameters and alarms. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 85 to 265 VAC and 100 to 300 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20V AC to 480V AC, CAT III or 20V AC to 690V AC, CAT II at 45 Hz to 70 Hz. The range of measurement voltage between Phase and Neutral is 20V AC to 277V AC, CAT III or 20V AC to 400V AC, CAT II at 45 Hz to 70 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has four digital inputs and dual relay outputs. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.24 inches (57 millimetres), height 3.78 inches (96 millimetres) and product weight 8.8 onces (250 g).