Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
PM5563 Meter, 2 ethernet, up to 63th H, 1,1M 4DI/2DO 52 alarms, DIN mounted image 2
PM5563 Meter, 2 ethernet, up to 63th H, 1,1M 4DI/2DO 52 alarms, DIN mounted image 3
PM5563 Meter, 2 ethernet, up to 63th H, 1,1M 4DI/2DO 52 alarms, DIN mounted image 4
MD01 thumbnail 1
PM5563 Meter, 2 ethernet, up to 63th H, 1,1M 4DI/2DO 52 alarms, DIN mounted thumbnail 2
PM5563 Meter, 2 ethernet, up to 63th H, 1,1M 4DI/2DO 52 alarms, DIN mounted thumbnail 3
PM5563 Meter, 2 ethernet, up to 63th H, 1,1M 4DI/2DO 52 alarms, DIN mounted thumbnail 4

PM5563 Meter, 2 ethernet, up to 63th H, 1,1M 4DI/2DO 52 alarms, DIN mounted

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
705,25 €
This price is valid until 31.12.24
EAN: 3606480614088
MPN: METSEPM5563
Package: 1

Technical Information

Item condition New
Manufacture name PM5563 Meter, 2 ethernet, up to 63th H, 1,1M 4DI/2DO 52 alarms, DIN mounted
Brand Schneider Electric
Categories Automatics and control
Country of origin IN
Harmonized System Code 9028 3090 00
Mounting method Built-in
Width 0 mm
Model Measurement transformer
Height 0 mm
Voltage type AC/DC
Measured value memory Yes
Indication Other
Frequency measurement Yes
Max. current (Imax) 10 A
Reactive power Yes
Accuracy class 0.2
Harmonics measurement Yes
Measuring range 20-690 V
Power factor Yes
Effective power Yes
Apparent power Yes
Step angle (cos phi) No
Supporting protocol for LON No
Supporting protocol for Modbus Yes
Max. value storage Yes
Min. value storage Yes
With communication interface RS-485 Yes
Calibrated No
Pulse output Optic
Pole type Three conductor/four conductor
Measurement type load profile Yes
Nominal current (In) 5 A
With communication interface KNX No
With communication interface according to EN 62056-21 No
Wth communication interface M-Bus No

Packing details

Packing level 1 3606480614088

Downloads

Description

This device is a DIN-mount energy meter without display. The meter provides Class 0.2S accuracy per IEC 62053-22 standard and 128 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 63rd Harmonic. Include 1.1 MegaBytes of memory for up to 14 selectable parameters with configurable interval and duration. This meter also feature the direct monitoring of neutral current. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 480 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20 to 690 VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 45 to 65 Hz. Communication protocol are Modbus RTU and ASCII 2 wires with RS485 port support plus Modbus TCP/IP, Ethernet/IP and BACnet/IP based on 10/100 Mbit/s, daisy chain Ethernet with RJ45 port support. The embedded communication capabilities allow the support of the DNP 3.0 protocol, the access to an onboard web server and a Serial to Ethernet gateway. The meter also has four digital inputs with WAGES support and two digital outputs. There are 52 configurable alarms and it supports eight tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 3.03 inches (77 millimetres), height 3.78 inches (96 millimetres) and product weight 15.9 onces (450 g).