Register to unlock your exclusive B2B prices and start shopping. Sign up now!
***RELAY TIME DELAYED DUR ON AT END OF IM image 1
***RELAY TIME DELAYED DUR ON AT END OF IM image 2
***RELAY TIME DELAYED DUR ON AT END OF IM image 3
***RELAY TIME DELAYED DUR ON AT END OF IM image 4
***RELAY TIME DELAYED DUR ON AT END OF IM thumbnail 1
***RELAY TIME DELAYED DUR ON AT END OF IM thumbnail 2
***RELAY TIME DELAYED DUR ON AT END OF IM thumbnail 3
***RELAY TIME DELAYED DUR ON AT END OF IM thumbnail 4

***RELAY TIME DELAYED DUR ON AT END OF IM

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
49,29 €
This price is valid until 24.12.24
EAN: 3606480377433
MPN: A9E16067
Package: 1
Box: 40

Technical Information

Item condition New
Manufacture name ***RELAY TIME DELAYED DUR ON AT END OF IM
Brand Schneider Electric
Categories Relays
Country of origin ID
Harmonized System Code 8536 4900 99
Mounting method DIN rail
Function Release-delay
Built-in height 81 mm
Type of excitation Analogue with single function
Width in number of modular spacings 1
Number of changeover switches 1
Control voltage 1 24-240 V
Control voltage 2 24 V
Type of control voltage 1 AC
Type of control voltage 2 DC
Frequency control voltage 1 50-60 Hz
Frequency control voltage 2 0 Hz
Voltage type of supply voltage AC
Supply voltage 24-240 V
1st interval unit Seconds/hours
2nd interval unit Seconds/hours
1st interval 0.1-100
2nd interval 0.1-360000
Nominal switching current at 250 V AC 21 A
Switch capacity incandescent lamps 0 W
Switch capacity fluorescent lamp DUO 0 VA
Switch capacity fluorescent lamp inductive 0 VA
Switch capacity fluorescent lamp parallel 0 VA
Number of contacts as normally closed contact 0
Number of contacts as normally open contact 0

Packing details

Packing level 1 3606480377433
Packing level 2 3606480377431

Downloads

Description

This Acti 9 iRTC is a Time delay relay. The time delay range is from 0.1s to 100h. It delays de-energizing of a load upon opening of an auxiliary contact (push button). The load is de-energized at the end of time delay T. The operating frequency is 50Hz or 60Hz. The Uc control and power supply voltage is from 24VAC to 240VAC +/-10% and 24VDC +/-10%. The single time delay cycle starts only upon release of an auxiliary contact (push button). The precision of the device is +/- 10% of the full scale. The Minimum duration of control impulse is 100ms. The maximum resetting time per voltage interruption is 100ms. The nominal switching current is 21A at 250VAC. The mechanical endurance under AC1 category is over 5 x 10exp6 switchning operations. The electrical endurance under AC1 category is over 10exp5 switchning operations. The type of excitation is analog (ou analogue) with single function. The device is flashing during time delay. It includes a changeover contact. The width in 9mm pitches is 2. The degree of protection is IP20. The dimensions are (W) 18mm x (H) 90mm x (D) 72mm. The weight is 65g. The operating temperature is -5°C to + 55°C. The storage temperature is -40°C to + 70°C.