Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals image 1
MD01 image 2
Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals image 3
Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals image 4
Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals image 5
Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals thumbnail 1
MD01 thumbnail 2
Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals thumbnail 3
Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals thumbnail 4
Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals thumbnail 5

Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
502,13 €
This price is valid until 31.12.24
EAN: 3389110363111
MPN: LU2BA0ES
Package: 1

Technical Information

Item condition New
Manufacture name Reversing power base, TeSys Ultra, 3P, 12A/690V, coil 48-72V AC/DC, without control terminals
Brand Schneider Electric
Categories Modular switches
Country of origin FR
Width 45 mm
Height 224 mm
Depth 126 mm
With transformer No
Rated operation power at AC-3, 400 V 5.5 kW
Number of command positions 3
Number of auxiliary contacts as normally open contact 1
Number of auxiliary contacts as normally closed contact 1
Suitable for emergency stop No
Rated operation current Ie 12 A
Number of indicator lights 0
Supporting protocol for LON No
Supporting protocol for TCP/IP No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for Modbus No
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for other bus systems No
External reset possible No
Rail mounting possible Yes
Rated control supply voltage at AC 50 Hz 48 V
Rated control supply voltage at AC 60 Hz 48 V
Rated control supply voltage at DC 48-72 V
Degree of protection (IP) IP20
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
With short-circuit release Yes
With fuse No
Type of electrical connection of main circuit Screw connection
Type of electrical connection for auxiliary- and control current circuit Screw connection
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Voltage type for actuating AC/DC
Type of motor starter Reversing starter
Rated operation power at AC-3, 230 V, 3-phase 3 kW
Rated power, 460 V, 60 Hz, 3-phase 5.5 kW
Rated power, 575 V, 60 Hz, 3-phase 5.5 kW
Rated operation current at AC-3, 400 V 12 A
Ambient temperature, upper operating limit 70 °C
Rated conditional short-circuit current, type 2, 400 V 50000 A
Rated conditional short-circuit current, type 2, 230 V 50000 A
Rated conditional short-circuit current, type 1, 480 Y/277 V 10000 A
Rated conditional short-circuit current, type 1, 600 Y/347 V 4000 A
Coordination class according to IEC 60947-4-3 Class 2

Packing details

Packing level 1 3389110363111

Downloads