Register to unlock your exclusive B2B prices and start shopping. Sign up now!
RFID SAFETY EDM AUTO START MULTI PAIRING image 1

RFID SAFETY EDM AUTO START MULTI PAIRING

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
122,17 €
This price is valid until 24.12.24
EAN: 3389119635837
MPN: XCSRC31AM12
Package: 1

Technical Information

Item condition New
Manufacture name RFID SAFETY EDM AUTO START MULTI PAIRING
Brand Telemecanique
Categories Sensors
Country of origin FR
Voltage type DC
Housing material Other
Suitable for safety functions Yes
Coating housing Uncoated
With status indication No
Ambient temperature -25-70 °C
Switching distance 35 mm
Number of semiconductor outputs with signalling function 0
Number of contact energized outputs with signalling function 0
Number of protected semiconductor outputs 0
Number of protected contact energized outputs 3
Type of interface for safety communication Other
Type of electric connection Connector M12
Type of switching output PNP
Explosion safety category for gas None
Explosion safety category for dust None
Construction type housing Cuboid
Protected switch distance OFF 20 mm
Protected switch distance ON 8 mm
Max. output current at protected output 100 mA
Mechanical mounting condition for sensor Other
Min. output current 60 mA
With monitoring function downstream switching devices No
Cross-/short circuit identification possible Yes
Degree of protection (IP) IP67
Type of actuation Magnet
Rated supply voltage at DC 24 V
Width sensor 15 mm
Diameter sensor 0 mm
Height of sensor 108.5 mm
Length of sensor 30 mm
Performance level according to EN ISO 13849-1 Level e
SIL according to IEC 61508 3

Packing details

Packing level 1 3389119635837

Description

This XCSRC RFID Contactless Safety Switch is designed for use as a safety interlock switch for guard door or protective casings monitoring and position detection on machines with low inertia. It has 2 NO Solid State PNP safety outputs (OSSDs). It is a standalone model with 2 possible new re-pairing of blank transponders, allowing a direct connection to the contactors without connection to a safety control unit (embedded Automatic start/restart and EDM monitoring). It has a high level of coding (unique code) according to EN/ISO 14119. Its integral LEDs offer a local Signaling, allowing it to clearly display the status of the device. Its PFHD reliability data is 5 x 10⁻¹⁰. It has a plastic body with M12 connector. Its IP65 / IP66 / IP67 / IP69K degree of protection and ECOLAB compatibility makes it ideal for heavy duty use in harsh conditions and hygiene environments. It also complies with EN/ISO 14119, EN/IEC 60947-5-2, EN/IEC 60947-5-3 standards. In Standalone operation or when associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.